Quadra-Fire CB1200 owner manual D.Blower Replacement, C. High Ash Fuel Content Maintenance, Task

Models: CB1200

1 44
Download 44 pages 36.37 Kb
Page 31
Image 31
C. High Ash Fuel Content Maintenance

R

CB 1200 Pellet Stove

C. High Ash Fuel Content Maintenance

Frequency: As needed

By: Homeowner

Task:

Poor quality pellet fuel, or lack of maintenance, can create conditions that make the firepot fill quickly with ashes and clinkers. This condition makes the appliance susceptible to overfilling the firepot with pellets which may result in smok- ing, sooting and possible hopper fires. Figure 31.1 shows an example where the firepot overfills, pellets back up into the feed tube and ash has accumulated in the firebox. Figure

31.2illustrates an inefficient and non-economical method of burning of fuel caused by poor quality pellet fuel. Figure 31.3 is showing the correct flame size when good quality, premium pellet fuel is burned.

If the ash buildup exceeds the half way point in the firepot

IMMEDIATE ATTENTION AND CLEANING IS REQUIRED.

Follow the detailed instructions found in this section for each step listed below.

Shut down the unit by turning down the thermostat and allow unit to completely cool down. (Do not unplug the unit, it can cause smoke spillage in the room).

Pull the heat exchanger cleaning rods. Section 10.7

Empty the firepot. Section 10.2

Clean the firebox. Section 10.4

Empty the ash drawer. Section 10.3

Dispose of the ashes. Section 10.6

Restart the appliance with premium grade fuel.

D.Blower Replacement

1.Convection Blower Replacement

a.Use proper shut down procedures to shut down the appliance and let it completely cool.

b.The convection blower is located at the bottom rear of the appliance. If an outside air kit is also installed, depending on your particular installation you may or may not have to remove the outside air flange. If you do, remove the 2 screws using a Phillips head screw- driver. You do not need to remove the flex pipe from the flange.

c.Remove the lower rear screen by removing the 4 screws securing the screen to the unit.

d.The motor is mounted on a removable bracket. Remove the 2 screws just above the motor and the whole assembly will tilt down and pull out.

e.Disconnect the wires from the blower. The wires coming from the wiring harness are white, red and tan and the wires coming from the blower are black, white and red. The white connects to white, the red to red and black to the tan color wire.

Firepot Overfills

Pellets Back Up

In Feed Tube

 

Ash Build Up in Firebox

 

Figure 31.1

 

Incorrect

 

Tall, Lazy Flame, Orange in Color

Figure 31.2

Correct

Correct Flame Size, Yellow/White in Color

Figure 31.3

Remove 2

Screws

 

 

 

 

Outside Air

 

 

Flex Hose

Remove 4

Screws

 

 

Convection Blower

 

 

Figure 31.4

September 21, 2006

7014-082B

Page 31

Page 31
Image 31