Quadra-Fire CB1200 CB 1200 Pellet Stove, Espaces, and Welcome to the Quadra-FireFamily, Mfg Date

Models: CB1200

1 44
Download 44 pages 36.37 Kb
Page 2
Image 2
CB 1200 Pellet Stove

CB 1200 Pellet Stove

R

and Welcome to the Quadra-Fire Family!

Hearth & Home Technologies welcomes you to our tradi- tion of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durabil- ity, and performance.

This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced technology to achieve the optimum operation of our stoves, inserts and fireplaces. And yet we are old- fashioned when it comes to craftsmanship. Each unit is

meticulously fabricated and gold and nickel surfaces are hand-finished for lasting beauty and enjoyment. Our pledge to quality is completed as each model undergoes a quality control inspection. From design, to fabrication, to shipping: Our guarantee of quality is more than a word, it’s Quadra- Fire tradition, and we proudly back this tradition with a Lim- ited Lifetime Warranty.

We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing Quadra-Fire.

With warm regards,

___________________________

___________________________

_________________________

___________________________

Alan Trusler

 

Dan Henry

t

Jason Olmstead

Steve Tate

Senior

Vice President

Vice President &

Vice President

 

Quadra-Fire

Dealer Channel

 

Advanced Technolgies

General Manager

 

Brand Manager

 

 

 

 

SAMPLE SERIAL NUMBER / SAFETY LABEL LOCATION:

Behind left side curtain on outside of hopper wall.

CAUTION: HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS. Operate this unit with fuel hopper lid closed. Failure to do so may result in emissions products' combustion from the hopper under certain conditions. Maintain hopper seal in good condition. Do no over fill the hopper.

ATTENTION: CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS. Opérez cet appareil avec le couvercle de la trémie fermé. Le défaut de ne pas suivre les instructions peut résulter, sous certaines conditions, en une combustion des émissions des produits venant de la trémie. Ne pas remplir la trémie trop pleine.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Listed by

O-T L

Beaverton

 

 

 

Report Rapport

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SERIAL NO. NUMÉRO DU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Oregon USA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CB 1200 Pellet Stove

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OMNI-Test Laboratories, Inc.

 

 

 

 

061-S-21-4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

007

 

 

 

 

 

 

 

 

 

 

 

Installation. This appliance has

 

Appareil de chauffage inséré de combustible solide/de

type de boulettes. Accepté dans l'installation

dans les maisons mobiles. Cet

 

Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile Home

 

 

been tested and listed for use in Manufactured Homes in accordance with OAR 814-23-9000 through 814-23-909.

 

appareil a été testé et enregistré pour l'usage dans les

Maisons Mobiles en accord avec OAR 814-23-

9000 jusqu'à 814-23-909.

 

 

Tested to: ASTM E1509, ORD-C-1482-M1990 Room Heating Pellet Burning Type, APFI, (UM) 84-HUD FOR

 

 

Testé à: ASTM #1509-95, ORD-C 1482-M1990

Room Heating.

Pellet Burning Type,

APFI, (UM) 84-HUD POUR

 

USE ONLY WITH PELLETIZED WOOD OR SHELLED FIELD CORN FUEL.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USAGE AVEC LES BOULETTES DE BOIS OU DE COMBUSTIBLE DE MAIS ÉCOSSÉ DES CHAMPS.

 

Input Rating: 40,000 Btu's/hr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Puissance de Rendement: 40,000 Btu's/hr

 

 

 

 

 

 

 

 

 

 

 

Electrical Rating:

115 VAC, 60 Hz, Start 4.6 Amps, Run 1.6 AMPS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Puissance Électrique: 115 VAC, 60 Hz, Début 4.6 Amps, Courir 1.6 Amps,

 

 

 

 

 

 

 

 

 

Route power cord away from unit. Do not route cord under or in front of appliance.

 

 

 

 

 

 

 

 

 

 

Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil.

 

DANGER: Risk of electrical shock. Disconnect power supply before servicing. Replace glass only with 5mm

 

 

DANGER: Il y a risque de décharge électrique. Déconnectez le fil électrique de la prise de contact avant le service.

 

 

 

Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur.

 

 

 

 

 

 

 

ceramic

available

from your

dealer.

To start, set

thermostat

above room

temperature, the stove will

light

 

 

 

 

 

 

 

 

 

 

 

Pour

allumer,

monter

la température du thermostat au

dessus

de

la température de la

pièce, le poêle s'allumera

 

automatically. To shutdown, set thermostat to below room temperature. For further instruction refer to owner's

 

 

 

 

 

automatiquement. Pour éteindre, descendre la température du thermostat en dessous de la température de la pièce. Pour des

 

manual.Keep viewing and ash removal doors tightly closed during operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

instructions supplémentaires, référez vous au manuel du propriétaire.

Gardez la porte d'ouverture et la porte des cendres

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fermées hermétiquement durant l'opération.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS /

 

LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ESPACES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

C

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

E

 

 

C

 

 

 

 

A

 

 

C

A

Back Wall to stove / Mur Arrière du poêle

 

 

 

2"/51mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

Side Wall to Cast Top / Mur De Côté du haut

 

6"/152mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CORNER INSTALLATION / NSTALLATION DU COIN :

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

Side Wall / Mur De Côté

 

 

 

 

 

2"/51mm

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

B

VERTICAL ADAPTER KIT INSTALLATION:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UN ASSEMBLAGE POUR ADAPTEUR POUR INSTALLATION VERTICALE:

Note 1: In residential installations,

when using

Parts 811-0580, (3"

-

3" Top

Vent Adapter) and

 

 

 

 

 

 

 

 

 

 

 

 

D

Back Wall to Flue Pipe / Mur Arrière tuyau rigide

 

3"/76mm

812-2690 (3" - 6" Top Vent Adapter Collar) 24 gauge 6" single wall flue connector may be used.

P

 

F

 

 

 

 

B

Side Wall to Cast Top / Mur De Côté du haut

 

6"/152mm

 

 

 

 

 

CORNER INSTALLATION WITH VERTICAL ADAPTER KIT:

 

 

 

 

 

 

Note 1: Dans les installations résidentielles, lorsque les pièces 811-0580, (dessus de l'adapteur de

 

 

 

 

 

 

 

 

 

 

D

INSTALLATION DU COIN AVEC UN ASSEMBLAGE D'ADAPTEUR VERTICAL:

ventilation 3" - 3") et 812-2690 (collier de l'adapteur de ventilation 3" - 6"), un tuyau connecteur de 6"

 

 

 

 

 

 

 

 

 

 

 

 

E

Side Wall / Mur De Côté

 

 

 

 

 

2"/51mm

pour mur simple de calibre 24 peut être utilisé.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALCOVE INSTALLATION / INSTALLATION DE L' ALCÔVE:

 

 

 

 

 

 

Note 2: In manufactured home installation, when using Part 811-0580, (3" - 3" Top Vent Adapter) and

 

 

 

 

 

 

 

 

 

 

A

Max. Alcove Depth: / La profondeur maximum de l'alcôve

 

36"/914mm

 

 

 

 

 

 

 

 

 

 

A

Back Wall to stove / Mur Arrière du poêle

 

 

 

2"/51mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

812-2690 (3' - 6" Top Vent Adapter Collar), use listed double wall flue connector.

An Outside Air Kit

 

 

 

 

 

 

 

 

 

 

 

 

B

Side Wall to Cast Top / Mur De Côté du haut

 

6"/152mm

(Part 811-0560 rear or 811-0570 floor), must be used with manufactured home installation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

Unit corner to diagonal wall /

 

 

 

 

 

2" (51mm)

Note 2: Pour l'installation dans les maisons préfabriquées, lorsque les pièces 811-0580 (dessus de

 

 

 

 

 

 

 

 

 

 

 

 

F

Top of Unit to Combustibles / Du poêle du haut combustibles

 

12.5"/318mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

l'adapteur de ventilation 3" - 3") et 812-2690 (collier de l'adapteurAde ventilation 3" - 6"), utilisez un

 

 

 

 

 

 

 

 

 

 

 

 

 

Alcove vertical installation / Installation verticale de l'alcôve

tuyau connecteur enregistré pour mur double. Un assemblage d'air extérieur (pièce 811-0560 arrière

 

 

 

 

 

 

 

 

 

 

 

 

D

Back Wall to Flue Pipe / Mur Arrière tuyau rigide

 

3"/76mm

au 811-0570 la plancer), doit être utilisé pour l'installation dans les maisons préfabriquées.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLOOR PROTECTION / PROTECTION DU SOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H*

 

*Non-combustible floor protection must extend beneath the flue pipe when installed with

*Un protecteur incombustible de plancher doit s'étendre sous le conduit de cheminée pour une

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

horizontal venting or under the Top Vent Adapter with vertical

 

installation.

installation de ventilation horizontale ou sous un adapteur de ventilation de dessus pour une

 

 

G

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED IN USA; REQUIRED IN CANADA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

installation verticale. ÉTATS-UNIS - RECOMMANDÉ; CANADA - REQUIRENT

 

 

 

 

 

 

 

I

 

Floor protector must be noncombustible material, extending beneath heater and to the

Le poêle doit être placé sur une assise non combustible s’étendant tout autour de lui, comme les

 

G = 2"/51mm

 

front/sides/rear as indicated. Measure front distance (I) from the surface of the glass door.

schémas l’indiquent. Mesurez la distance du devant (I) de la surface de la porte vitrée.

 

 

H* = 2"/51mm

 

 

 

 

 

 

 

 

 

 

 

 

U.S. ENVIRONMENTAL PROTECTION AGENCY This model is exempt from EPA certification under 40 CFR 60.531 by definition [Wood Heater (A) "Air-to-Fuel Ratio"].

 

I = 6"/152mm

 

 

1445 Highway North

 

2006

 

2007

 

2008

 

JAN

FEB

MAR

 

APR

MAY

JUNE JULY AUG

SEPT

OCT NOV

DEC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Colville, WA 99114

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.quadrafire.com

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE

 

 

Made in China/Fait Aux Chine

 

 

 

 

 

250-3182

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Testing Lab & Report Number

Serial Number

Model

Mfg Date

Page

7014-082B

September 21, 2006

Page 2
Image 2
Quadra-Fire CB1200 owner manual CB 1200 Pellet Stove, Espaces, and Welcome to the Quadra-FireFamily, Mfg Date