– 6 –
ELECTRICAL CONNECTIONS
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE
PORTION OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW
LOCKOUT/TAGOUT PROCEDURES.
A hole for 3/4"-trade-size conduit is located at the top of the pedestal. Make electrical connections per the
wiring diagram located on the inside of the top cover.
Three-Phase Mixer:
• Connect fi eld supply lead wires to L1, L2 and L3.
• Connect ground wire to ground lug on the mixer.
INITIAL CHECKS
Check Lubrication Before Use
This mixer is shipped with oil in the transmission. Check oil level before starting mixer (Fig. 2). Refer to
Lubrication on page 23 for applicable lubrication procedures.
Operation
1. Turn the SPEED dial pointer to STIR.
2. Apply power to the mixer. With the bowl locked into place, the bowl support all the way up and bowl
guard closed, momentarily run the machine by pushing the START and then STOP buttons.
3. Verify that the motor is turning counterclockwise (Fig. 2). If not, reverse any two lead wires.
4. Verify that the bowl lift actuator raises and lowers per the switch direction arrows.
Fig. 2