4-4. Troubleshooting
|
|
|
|
|
|
|
|
|
|
|
|
| Trouble | Remedy | |
|
|
|
|
|
|
|
|
Wire does not feed; | Check circuit breaker CB1 and fuse F1. Reset CB1 or replace F1 if necessary (see Section | ||
available. |
| ||
|
|
|
|
|
|
| Check sensing lead connection. |
|
|
|
|
|
|
| Check gun trigger plug connection. |
|
|
|
|
|
|
| Check gun trigger. See gun Owner’s Manual. |
|
|
|
|
|
|
| Have Factory Authorized Service Agent check drive motor and control board PC1. |
|
|
|
|
Wire feeds erratically. | Readjust hub tension (see Section | ||
|
|
|
|
|
|
| Readjust drive roll pressure (see Section |
|
|
|
|
|
|
| Use correct size drive roll (see Parts Listing) |
|
|
|
|
|
|
| Clean or replace dirty or worn drive roll (see Section |
|
|
|
|
|
|
| Remove weld spatter around nozzle opening. |
|
|
|
|
|
|
| Replace contact tip or liner. See gun Owner’s Manual. |
|
|
|
|
|
|
| Have Factory Authorized Service Agent check drive motor and control board PC1. |
|
|
|
|
Wire feeds as soon as power is applied. | Check gun trigger. See gun Owner’s Manual. | ||
|
|
|
|
Wire stubbing on low end using a con- | Make sure CC/CV switch is in CC position (see Section | ||
stant current power source. |
| ||
|
|
|
|
|
|
| Increase output setting of power source. |
|
|
|
|
Inaccurate optional IPM meter. | Calibrate meter (see Section | ||
|
|
|
|
Optional meters not working. | Have Factory Authorized Service Agent check meter board PC4 and control board PC1. | ||
|
|
|
|
Gas does not flow; wire feeds. | Check optional gas valve and flowmeter. | ||
|
|
|
|
|
|
| Have Factory Authorized Service Agent check control board PC1. |
|
|
|
|
Gas does not stop flowing; wire feeds. | Adjust optional flowmeter. | ||
|
|
|
|
|
|
| Have Factory Authorized Service Agent check control board PC1. |
|
|
|
|