Hobart SM6T2 ML-110857 manual Service, Symptom, Possible Cause

Models: SM6T2 ML-110857

1 12
Download 12 pages 42.55 Kb
Page 12
Image 12
SERVICE

SYMPTOM

POSSIBLE CAUSE

Inadequate rinse.

1.

Dirty line strainer causing reduced water flow. Turn off water

 

 

supply, remove strainer cap, withdraw and clean screen.

 

 

Reassemble.

 

2.

Low supply line pressure.

 

3.

Excessive mineral deposits throughout wash and rinse system.

 

 

Deliming may be necessary.

 

 

 

Leaking valve (except solenoid

1.

Foreign material preventing proper valve operation. NOTE: A

type).

 

critical period is soon after installation when pipe compound or

 

 

metal shavings may lodge at the valve seat. Shut off supply

 

 

line. Unscrew and lift bonnet from valve body. Clean valve

 

 

and reassemble.

 

2.

If a solenoid valve is malfunctioning, it is recommended that

 

 

you contact Service.

 

 

 

No wash tank heat.

1.

Circuit breaker to heater tripped.

 

2.

Because of a low water condition, the thermostat turned the

 

 

heater off. To reset the thermostat, refer to HEATER, page 7.

 

3.

Over-temperature thermostat may have tripped. Contact

 

 

Service.

 

 

 

No or slow fill.

1.

Dirty line strainer causing reduced water flow. Turn off water

 

 

supply, remove strainer cap, withdraw and clean screen.

 

 

Reassemble.

SERVICE

Contact your local Hobart Service Office for any repairs or adjustments needed on this equipment.

FORM 34047 Rev. A (July 2000)

– 12 –

PRINTED IN U.S.A.

Page 12
Image 12
Hobart SM6T2 ML-110857 manual Service, Symptom, Possible Cause