3-2. Reset Button And Low Battery Indicator

. The auto-darkening lens turns on

(darkens) automatically when welding begins and turns off 15 − 20 minutes after welding stops.

1

2

1

Reset Button

 

 

Press Reset button to check if the lens

 

 

is working properly.

 

 

When the Reset button is pressed, the

 

 

lens should darken twice and return to

 

 

the clear state. Do not use the helmet

 

 

if the lens does not function as de-

 

 

scribed. (See Section 9, Trouble-

 

 

shooting.)

 

 

2

Low Battery Indicator

The low battery indicator lights when 2−3 days of battery life remain.

If battery power is low, replace with CR2450 lithium batteries (2 required) (Hobart Part No. 770 284) (see Sec- tion 6).

3-3. Lens Delay Control

1

1 Lens Delay Control

The lens delay control is used to ad- just the time for the lens to switch to the clear state after welding.

The delay is particularly useful in eliminating bright after-rays present in higher amperage applications where the molten puddle remains bright momentarily after welding. Lens delay adjusts from min (0.10 second) to max (1.0 second.).

OM-240 362 Page 4

Page 6
Image 6
Hobart Welding Products XVX manual Reset Button And Low Battery Indicator, Lens Delay Control