3-5. Sensitivity Control

1 Sensitivity Control

Weld Mode

Use control to make the lens more respon- sive to different light levels in various weld- ing processes. Use a Mid-Range or

130−50% sensitivity setting for most ap-

plications.

 

It may be necessary to adjust helmet sensi-

 

 

tivity to accommodate different lighting con-

 

 

ditions or if lens is flashing On and Off. Ad-

 

 

just

helmet sensitivity as follows:

 

 

. Adjust helmet sensitivity in lighting con-

 

 

 

ditions helmet will be used in.

 

 

S

Turn sensitivity control to lowest

 

 

 

setting.

 

 

S

Press Reset button to turn helmet On.

 

 

 

Helmet lens will darken twice and then

 

 

 

clear.

 

 

S Face the helmet in the direction of use,

 

 

 

exposing it to the surrounding light con-

 

 

 

ditions.

 

 

S Gradually turn sensitivity setting clock-

 

 

 

wise until the lens darkens, then turn

 

 

 

sensitivity control counterclockwise

 

 

 

until slightly past setting where lens

 

 

 

clears. Helmet is ready for use. Slight

 

 

 

readjustment may be necessary for

 

 

 

certain applications or if lens is flashing

 

 

 

on and off.

 

 

Grind Mode

 

 

. Do not weld in the Grind mode; the lens

 

 

 

will not darken.

 

 

To use the Grind mode, turn the Sensitivity

 

 

control clockwise to the far right position

 

 

(Grind). To resume welding, return the con-

 

 

trol to the desired sensitivity setting.

 

 

 

 

 

 

 

Recommended Sensitivity Settings

 

 

 

 

Stick Electrode

Mid-Range

 

 

 

 

Short Circuiting (MIG)

Low/Mid-Range

 

 

 

 

Pulsed & Spray (MIG)

Mid-Range

 

 

 

 

Gas Tungsten Arc (TIG)

Mid/High-Range

 

 

 

 

Plasma Arc Cutting/Welding

Low/Mid-Range

 

 

 

 

Grind Mode

Grind Position − Far Right (Clockwise)

 

 

 

 

 