Operations (Step 3 Setting Using the V.Networks Controller)

3-5 Image Quality Setting (Continued)

Image Quality Setting (Continued)

Item

Function/Set Value

Initial Value

 

 

 

Sense Up

This function is used to increase the sensitivity by extending

OFF

 

the exposure time. Increasing this value slows the shutter speed

 

 

and motion may appear unnatural.

 

 

When the item "SHUTTER" is set to "1/250" or more, the

 

 

SENSE UP item does not work.

 

 

Setting values: OFF, x2, x4, x8, x16, x24, x32

 

 

• When SENSE UP is activated, the picture may become rough

 

 

and whitish, and subject to white blemishes.

 

 

• When the setting of the "SENSE UP" function is not OFF,

 

 

flicker may appear on the screen under fluorescent light or

 

 

mercury lamps. This is due to the principles of the SENSE

 

 

UP, and is not a malfunction.

 

 

• There may be cases where flicker can not be reduced even

 

 

under the following conditions: 1) Shutter speed is set at 1/100

 

 

in areas where the commercial electric current frequency is 60

 

 

Hz. 2) The shutter speed is set at 1/60 in areas where the com-

 

 

mercial electric current frequency is 50 Hz.

 

 

 

 

ExDR Mode

The ExDR function synthesizes pictures captured at a shutter

OFF

 

speed of 1/100 and those captured at higher shutter speeds to

 

 

help monitor objects having large differences in brightness lev-

 

 

els.

 

 

When the "SHUTTER" function is set to "1/250" or a higher,

 

 

this function does not work.

 

 

OFF : Turns the ExDR function off.

 

 

ON : Turns the ExDR function on.

 

 

• When the ExDR function is on, flicker may appear on the

 

 

screen under fluorescent light or mercury lamps. This is due

 

 

to the principles of the ExDR, and is not a malfunction.

 

 

• There may be cases where flicker cannot be reduced even

 

 

under the following conditions: 1) Shutter speed is set at 1/

 

 

100 in areas where the commercial electric current frequency

 

 

is 60 Hz. 2) The shutter speed is set at 1/60 in areas where

 

 

the commercial electric current frequency is 50 Hz.

 

 

 

 

ExDR Level

This function sets which section of the object is to be displayed

0

 

in the easiest-to-view

 

 

brightness level in the ExDR mode.

 

 

 

 

62