Alarm Output

 

Item

 

Function/Set Value

Initial Value

8 Output 1/

This section describes the setting procedures for alarm output.

OFF

 

Output 2

Set Values

: ON, OFF

 

 

Output Value

Select the alarm output method.

—

 

 

Output OFF : Output alarm signals when the Alarm Output 1

 

 

 

 

or Alarm Output 2 terminal is connected to the

 

 

 

 

GND terminal.

 

 

 

Output ON : Output alarm signals when the Alarm Output 1

 

 

 

 

or Alarm Output 2 terminal and the GND terminal

 

 

 

 

are disconnected from each other.

 

 

Pattern

Level

: Continue output of alarm signals throughout the

—

 

 

 

alarm input process.

 

 

 

Momentum : Output alarm signals only at the specified time.

 

 

 

 

Specify time using the Return Interval item.

 

 

 

 

 

 

Interval

For setting the output interval when the Output Pattern item is

—

 

 

set to Momentum.

 

 

 

This is disabled when the Output Pattern item is set to Level.

 

 

 

 

 

9 Output 1

Upon pressing the Output button, alarm signal output will be

—

 

force output/

sent from the alarm output terminal on the ceiling mount.

 

 

Output 2

This is used for checking the alarm operation.

 

 

force output

Notes

 

 

 

 

 

 

•Output is disabled when the Output Pattern item is set to "Level".