Alarm Output

 

Item

 

Function/Set Value

Initial Value

8 Output 1/

This section describes the setting procedures for alarm output.

OFF

 

Output 2

Set Values

: ON, OFF

 

 

Output Value

Select the alarm output method.

 

 

Output OFF : Output alarm signals when the Alarm Output 1

 

 

 

 

or Alarm Output 2 terminal is connected to the

 

 

 

 

GND terminal.

 

 

 

Output ON : Output alarm signals when the Alarm Output 1

 

 

 

 

or Alarm Output 2 terminal and the GND terminal

 

 

 

 

are disconnected from each other.

 

 

Pattern

Level

: Continue output of alarm signals throughout the

 

 

 

alarm input process.

 

 

 

Momentum : Output alarm signals only at the specified time.

 

 

 

 

Specify time using the Return Interval item.

 

 

 

 

 

 

Interval

For setting the output interval when the Output Pattern item is

 

 

set to Momentum.

 

 

 

This is disabled when the Output Pattern item is set to Level.

 

 

 

 

 

9 Output 1

Upon pressing the Output button, alarm signal output will be

 

force output/

sent from the alarm output terminal on the ceiling mount.

 

 

Output 2

This is used for checking the alarm operation.

 

 

force output

Notes

 

 

 

 

 

 

Output is disabled when the Output Pattern item is set to "Level".