VCC
R
Sensor Connection Example 1

3. Connection to Alarm Input/Output Terminal

1 2

Flathead

Alarm Signal

ScrewdriverCable

3

Flathead

Screwdriver

4

1

Connect the alarm input/output terminals to external devices such as sensors and buzzers.

1 Loosen the screws on both edges of the terminal block using a flathead screwdriver, followed by dismantling it as shown in the left diagram.

2 Strip the coating of the alarm signal cable by about 4mm before inserting it into the terminal.

3 Turn the screw on the side to fasten the alarm signal cable.

4 Upon fastening the alarm signal cable, re- install the terminal block that has been dismantled in Step 1.

Note

Cable Specifications

50 m or shorter in length UL1007, UL1015 or equivalent AWG#22 to AWG#18 or equivalent

Caution

Due to external noise, the cable may not function properly even when the cable length is less than 50 m. In this case, use a shielded cable or take measures such as keeping the cable away from the noise source.

This terminal is for connecting with a sensor, infrared, door or metallic, or a manual switch.

VN-C655

 

 

DC18V

 

 

R

Terminal

 

1 or 2

 

 

OUT

 

18V

0.6mA

 

Grounding GND

 

Terminal

 

Input Requirements

No-voltage relay input or NPN open collector

input

The polarity of the input detection can be

selected via software.

Make/Break/Toggle (at least 500 ms)

(Alarm Input Equivalent Circuit)

 

Sensor

 

Connection

 

Example 2

 

Relay,

OUT

switch,

etc.

GND

 

Circuit current at low level: 0.6 mA

Voltage applied at high level: 18 V

15