JVC VN-C655 Alarm 1/Alarm Message Packet, Available, Alarm FTP, Relay Alarm, Retry 1 to, List

Models: VN-C655

1 116
Download 116 pages 43.49 Kb
Page 37
Image 37

 

Item

 

Function/Set Value

Initial Value

1 Alarm 1/Alarm 2

(Continued)

 

 

Message Packet

For setting whether to send alarm packets to the PC when there

Not Available

 

 

is alarm input.

 

 

 

 

Not Available : Do not send alarm packets.

 

 

 

Available

: Send alarm packets.

 

 

Alarm FTP

For operation according to the [Alarm FTP] in the FTP Client

Not Available

 

 

feature when there is alarm input. Please refer to FTP Client

 

 

 

Settings (Page 47) for details on alarm FTP.

 

 

 

Set Values: Available, Not Available

 

2 Relay Alarm

Set here to enable the relay alarm function, which is activated

Not Available

 

 

when 2 alarms are received within a preset time interval.

 

 

 

The sequence and time interval for the alarm input can be specified.

 

 

 

When [Alarm Output] is selected, alarm signal output will be

 

 

 

sent to the alarm output terminal on the ceiling mount accord-

 

 

 

ing to the output port settings.

 

Notes

A second alarm input enables this relay alarm function, and alarm will not be activated for this second input.

Unless the alarm output in the "Alarm Output" tab is

enabled, this function will not be activated even if alarm output is selected in the alarm input settings. (Page 39)

Alarm Output * Please refer to the [Alarm 1/2] item for details on the set val- *Please

• Go to a preset position

ues.

refer to

• Return Mode

 

the [Alarm

• Interval

 

1/2] item

• Black & White

 

for the

• Message Packet

 

initial

• Alarm FTP

 

values.

3 Retry (1 to 3)

For setting the no. of times alarm notification is to be sent to

1

 

the "V.Networks Controller". (Set Value: 1 to 3)

 

 

Note

 

 

• Alarm notification may fail, depending on the LAN

 

 

environment in use. If it fails, set the value for alarm

 

 

notification to "3". In this case, alarm by the "V.Networks

 

 

Controller" itself is set off only once.

 

 

 

 

4 List

Press here to display the IP address of the PCs to which an

 

alarm notification is sent. ("Distribution Address List" Screen)

 

 

To delete a distribution address, select the IP address to de-

 

 

lete, followed by pressing the Delete button.

 

 

Notes

 

The list allows setting of up to 10 addresses.

Message packets will not be sent out when there are 11 or more addresses.

37

Page 37
Image 37
JVC VN-C655 Alarm 1/Alarm Message Packet, Available, Alarm FTP, Relay Alarm, Interval Black & White, Retry 1 to, List