Settings (Step 2 Network Settings)

2-4 Other Settings Using the "VN-C655U Setup Tool" (3. Alarm Setting) (Continued)

 Alarm Input

 

Item

 

Function/Set Value

Initial Value

1 Alarm 1/Alarm 2

This section describes setting procedures for alarm input.

 

Mode

For selecting whether to enable or disable the input signals.

Not Available

 

 

Set Values : Available, Not Available

 

 

Detect Mode

For selecting the method for detecting input signals.

Make

 

 

Make : Detect input signals at the "Make" contact point.

 

 

 

Break : Detect input signals during "Break".

 

 

 

Toggle : Detect input signals at both "Make" and "Break".

 

 

Alarm Output

For selecting whether to output from the alarm output terminal

Not Available

 

 

when there is alarm input.

 

 

 

Not Available : Do not output from the alarm output terminal.

 

 

 

Alarm Output 1 : Send output from the Alarm Output 1 terminal.

 

 

 

Alarm Output 2 : Send output from the Alarm Output 2 terminal.

 

 

 

Note

 

 

 

 

• Unless the alarm output in the "Alarm Output" tab is enabled,

 

 

 

this function will not be activated even if alarm output is

 

 

 

selected in the alarm input settings. (Page 39)

 

 

 

 

 

 

Go to a preset

For setting whether to move to the preset position when there

Not Available

 

position

is alarm input.

 

 

 

 

Not Available : Do not move to the preset position.

 

 

 

Home

: Move to the home position.

 

 

 

1 to 99

: Move to the preset position.

 

 

Return Mode

For setting whether to return the camera that has moved to the

Not Available

 

 

preset position upon the alarm input back to the home position.

 

 

 

Use [Return Interval] to set the time interval before returning

 

 

 

the camera to its home position.

 

 

 

Not Available : Do not return to home position.

 

 

 

Return

: Return to home position.

 

 

 

Event

: Return to home position if operation is not in

 

 

 

 

the manual mode.

 

 

Interval

For setting the time interval before the camera returns to its

0

 

 

home position when [Return Mode] is set to "Return".

 

 

 

Set Value : 0 to 65535 sec

 

 

Black & White

For switching from the Color to Black & White mode when there

Not Available

 

 

is alarm input.

 

 

 

 

Not Available

: Do not switch between Black & White/Color mode.

 

 

 

Color

: Color mode at all times.

 

 

 

Black & White : Black & White mode at all times.

 

 

 

Auto

: Switch automatically between Black & White

 

 

 

 

and Color mode according to the brightness

 

 

 

 

of the object.

 

Note

When Auto is selected, switching may fail in some cases due to the lighting conditions or angle of view. In order to ensure that switching is properly performed, it is recommended that signals from an external sensor (sold separately) be input to the alarm terminal of this camera.