Alarm In

For specifying the camera operation upon input of alarm signals.

1IN1/IN2

On : Detect Mode

(Set value: Make, Break, Toggle)

: Alarm Out

(Set value: Not Available, OUT1, OUT2)

:Go to a Preset Position

(Set value: Not Available, Home, Position 1 to Position 99)

:Return Mode

(Set value: Not Available, Return, Event)

: Return Interval

(Set value: 1 to 65535 seconds)

: Black & White

(Set value: Not Available, Color, Black

&White, Auto)

:Message Packet

(Set value: Available, Not Available)

:FTP

(Set value: Available, Not Available)

Off : Do not use Alarm 1 and Alarm 2.

2Relay Alarm On : Alarm Out

(Set value: Not Available, OUT1, OUT2)

:Go to a Preset Position

(Set value: Not Available, Home, Position 1 to Position 99)

:Return Mode

(Set value: Not Available, Return, Event)

:Return Interval

(Set value: 1 to 65535 seconds)

:Black & White

(Set value: Not Available, Color, Black

&White, Auto)

:Message Packet

(Set value: Available, Not Available)

:FTP

(Set value: Available, Not Available)

Off : Do not use Relay Alarm.

Other Triggers

For setting alarm activation via methods other than alarm input.

3Preset Position On : Alarm Output

(Set value: Not Available, OUT1, OUT2)

:Black & White

(Set value: Not Available, Color, Black & White, Auto)

:Massage Packet

(Set value: Available, Not Available)

Off : Do not use "Preset Position" Alarm.

4Black & White On : Alarm Out

(Set value: Not Available, OUT1, OUT2)

:Go to a Preset Position

(Set value: Not Available, Home, Position 1 to Position 99)

:Return Mode

(Set value:Not Available, Return, Event)

:Return Interval

(Set value: 1 to 65535 seconds)

:Massage Packet

(Set value: Available, Not Available)

Off : Do not use Black & White Alarm.

Alarm Out

For performing setting related to output during an alarm activation.

5OUT1/OUT2

On : Output Value

(Set value: ON, OFF)

:Pattern

(Set value: Level, Momentum)

:Momentum Interval

(Set value: 1 to 5000 milliseconds)

Off : Do not output alarm.

Notes

Set output settings according to settings of the device for which alarm output is sent to.

When alarm setting is complete, always check to ensure that the alarm is functioning correctly.