C L E A N I N G / M A I N T E N A N C E

C L E A N I N G / M A I N T E N A N C E

R E P L A C I N G T H E F I L T E R

WARM MIST CLEANING AND

MAINTENANCE INSTRUCTIONS

The following maintenance procedures must be routinely followed in order to ensure proper, efficient operation of your humidifier. The unit WILL FAIL if it is not cleaned properly.

When the unit is in use, daily and weekly maintenance is recommended. Regular weekly cleaning prevents scale buildup on the heating element and tray. It also prevents micro-organisms from growing on the tray and tank. This ensures that maximum efficiency will be achieved.

We cannot over-emphasize how essential proper cleaning is to the maintenance and continued use of your unit and to the avoidance of algae or bacteria build-up.

Daily Maintenance

Allow to cool before maintenance.

1.Before cleaning, set the control to OFF position and unplug the unit from the electrical outlet.

2.Remove the water tank then unlock the misting chamber by rotating the safety lock towards the front of the unit. Lift mist chamber from the unit’s base. Now lift the tray from the base.

3.Empty water and minerals from the tray and place in the top rack of the dishwasher. This will remove any sediment and dirt that has accumulated in the tray.

NOTE: It is imperative that the tray is cleaned properly.

The tray is dishwasher safe (top rack ONLY) for easy cleaning.

4.Wipe the heating element clean with a soft cloth after it has had a chance to cool.

5.Replace misting chamber and engage safety lock.

The Electronic Thermal Control Heating element is lined with

a Teflon® coating that is designed to provide the easiest cleaning and prolong the operating efficiency of the humidifier. DO NOT use any metal or hard objects to clean the Heating Element. Never use detergents, gasoline, kerosene, glass cleaner, furniture polish, paint thinner or other household solvents to clean any part of the humidifier.

Figure 2

A. Removable Tray

B

A

B. Water Purification Filter

 

C. Humidifier Base

 

C

Weekly Maintenance
Remove scale: Allow to cool before maintenance.

1.Repeat steps 1-5 in the Daily Maintenance section.

2.Clean the tray by partially filling the tray with one 8-oz cup of undiluted white vinegar. Let solution stand 20 minutes, cleaning all interior surfaces with a soft brush. Dampen

a cloth with undiluted white vinegar and wipe out entire tray to remove scale.

3.Rinse with clean warm water to remove scale and the white vinegar solution before beginning to disinfect the tank.

4.Wipe the heating element clean with a soft cloth after it has had a chance to cool.

Disinfect tank:

1.Fill tank with 1/2 teaspoon of chlorine bleach and 1/2 gallon of water.

2.Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces.

3.Empty the tank after 20 minutes, and rinse well with water until the bleach smell is gone. Dry with a clean cloth or paper towel.

4.Refill the water tank with cool water; replace the housing and water tank. Repeat ALL Operating Instructions.

REPLACING THE WARM MIST

WATER PURIFICATION FILTER

The water purification filter is used to trap minerals in your water and provide a clean moisture output. The filter life is determined by the average daily use of your humidifier and the water hardness in your area. Areas with hard water will require more frequent replacement of the filter. It is strongly recommended that the filter be replaced at least every 2-3 months (depending on use) or when the heating element is starting to gather minerals on it.

Hands should be cleaned immediately after removal of filter. Keep away from eye’s and mouth.

To Replace the Filter: Allow to cool before maintenance.

1.Switch the humidifier OFF and unplug. Remove the tank, drain any water from the base, lift out the used filter, and throw it away.

2.Remove the protective bag from the new filter and install the filter into the base (see Figure 2). Replace the tank, and plug the cord into the electric outlet. When installing the filter for the first time, wait 15 minutes for the water to flow through the filter before switching the unit ON.

You can obtain a new filter by calling 1-800-5-HOLMES in the USA or by visiting your nearest retailer or authorized service center. This humidifier takes model WMF50 replacement filter.