1Press the pushbutton switch quickly 5 times.

INSTALLATION INSTRUCTIONS

The HAI UPB™ Appliance Module is simply plugged into a standard wall outlet.

Load Information

The total load of the UPB™ controlled outlet must not exceed 15 Amps or ½ Horsepower.

Switch Trigger Operation

The Appliance Module can be configured to sense the load’s local on/off switch (switch trigger) to turn the load on even after it was turned off via UPB™ control. By default, the Appliance Module has the switch trigger operation disabled.

Note: This feature may not work for all types of loads (e.g. fluorescent lighting loads).

HAI APPLIANCE MODULE OPERATION

The HAI Appliance Module has many configurable items that can be set using the UPB™ UPStart configuration software. The following describes the operation of the HAI Appliance Module in its factory default configuration.

LED Indicator

The HAI UPB™ Appliance Module comes equipped with a multi-color LED indicator that is normally lit to blue when the load is off. The LED will turn off when the load is turned on.

Test Mode

The Appliance Module’s controlled outlet can be tested using the Test Mode. The Appliance Module can be put into test mode by the following steps:

Step

Operation

1Press and hold the pushbutton for at least 3 seconds to enter Test Mode.

2The HAI UPB™ Appliance Module will continuously blink its LED magenta to indicate that it is in Test Mode. Note: the appliance module will automatically exit Test mode after 5 minutes.

3Press the pushbutton 1 time to turn the UPB™ controlled outlet on and off.

4Press and hold the pushbutton for at least 3 seconds to exit Test Mode.

Setup Mode

To configure the HAI UPB™ Appliance Module using an HAI controller or a PC running the UPB™ UPStart configuration software, it must be put into Setup Mode as follows:

Step

Operation

1Press the pushbutton switch quickly 5 times.

2The HAI UPB™ Appliance Module will cycle the load one time and blink its LED blue to indicate that it is in Setup Mode. Note: the appliance module will automatically exit Setup mode after 5 minutes.

Reset to Factory Default Settings

To reset the HAI UPB™ Appliance Module to factory default settings:

Step

Operation

1On the HAI UPB™ Appliance Module that you want to reset to factory defaults, press the pushbutton switch quickly 5 times.

2The HAI UPB™ Appliance Module will cycle the load one time and blink its LED blue to indicate that it is ready to be set to factory defaults.

3Press the pushbutton switch quickly 10 times to reset to factory default setting.

4The HAI UPB™ Appliance Module will cycle the load one time and blink its LED red to indicate that it has been reset.

5Press the pushbutton switch once more to stop the LED from blinking.