Figure 6
Drip Loop
Maintenance
Figure 7
PVC Tubing |
|
Inserts Here | Back Plate |
| |
Impeller | Housing |
Pump Inlet |
|
Front Plate |
|
Suction Feet |
|
Flow |
|
Control |
|
Lever |
|
Troubleshooting |
|
• To clean the pump:
Unplug from electrical outlet. Remove it from the base of the fountain. Use a small brush or stream of water to remove any debris. (Fig 7)
•To keep water clean:
Periodically change water and clean the product according to the water condition. Keeping the water clean prevents the water from becoming sticky and forming
•To clean off hard water deposits on the base:
Soak the container in a mixture of vinegar and water to clean and remove any mineral
•Keeping the water at an optimum level:
Add water periodically to keep water level at an optimum level to avoid shortening the life of the pump.
NOTE: Never let the pump run dry, as this will shorten the life of the pump.
•Fountain Storage
Unplug the fountain from the electrical outlet, empty the water, and store fountain in a dry, cool place.
Caution: All servicing of this fountain must be performed by authorized HoMedics service personnel only.
•If the pump fails to operate, check the follow- ing:
Check the circuit breaker, or try a different outlet to make sure the pump is
getting electrical power.
NOTE: Always disconnect from electrical outlet before handling the pump.
•If the pump gurgles, spews, or “burps”:
Check the water level to make sure the pump has enough water to function.
•Obtaining a desired water level:
Check the water level daily the first week to measure the rate of evaporation;
refill with water as needed.
•If water is splashing outside the fountain:
Adjust the flow control lever to a lower setting on the pump.