Homelite HL454HP manual Fault Finding, Certificate Of Conformity, Ec Declaration Of Conformity

Models: HL454HP

1 8
Download 8 pages 22.41 Kb
Page 7
Image 7
FAULT FINDING

FAULT FINDING

PROBLEM

SOLUTION

 

 

Engine will not start

Check there is ample clean, fresh fuel in the tank.

 

Check the cutter blade is not fouling the ground preventing free rotation.

 

 

 

Engine will not stop

Check the Operators Presence Control (OPC) lever is fully released.

 

Remove spark plug lead to stop engine using insulated gloves and refer to dealer.

 

 

 

 

Stop the engine and disconnect the spark plug lead using heat resistant gloves.

Failure to cut grass properly

 

Check blade attachment bolt is tight.

 

 

 

Check condition of blade. If seriously worn or damaged replace with a new one.

 

 

 

Stop the engine and disconnect the spark plug lead using heat resistant gloves.

 

 

 

Check and make sure there is no build up of grass inside the casing.

 

 

 

Check grass catcher is allowing air to flow through the fabric; if it is clogged it should be washed

Failure to collect grass properly

carefully.

 

If the grass catcher is not clogged raise the height of cut to increase airflow.

 

 

 

Check to ensure the engine is running at the correct speed, (approximately 3000rpm).

 

 

 

If conditions are too severe to use the grass catcher, remove it and work with the deflector in position.

 

 

Machine vibrates excessively

This will certainly indicate that the blade has become badly damaged. Stop the engine, disconnect the

spark plug lead and examine the blade assembly. Refer to your local dealer.

 

CERTIFICATE OF CONFORMITY

EC DECLARATION OF CONFORMITY

The company

GGP ITALY SPA - Via del Lavoro, 6

 

 

31033 Castelfranco V.to (TV) ITALY

Certify that the lawnmower, walk behind with

HL454HP type ESL 464

combustion engine

HL454SP type ESL 464 TR

Widht of cut

45 cm

 

Engine

SUMEC • M 150

Tested by

SNCH, 11 route de Luxembourg

Conforms to the specifications of directives

L-5230 SANDWEILER

98/37/EEC

 

 

 

89/336/EEC ~ 2004/108/EC - 2000/14/EC

Conformity assessment procedure followed

ANNEX VI

 

Measured sound power level

95 dB(A)

 

Guaranteed sound power level

96 dB(A)

 

Reference to harmonised standards

EN 836 - EN 292-2- EN 1033 - EN ISO 3767

Sound pressure level at the ear measured in compli-

EN ISO 14982

 

85 dB(A)

 

ance with 81/1051/EEC

 

Viration level at the handle (EN 1033)

6 m/s2

 

 

 

 

Castelfranco Veneto (TV) - ITALY

01-10-2008

S. Ferrari (General Manager)

Page 7