Homelite HP155A, UT65052-A owner manual Wiring Diagram, Specifications

Models: HP155A UT65052-A

1 16
Download 16 pages 1.66 Kb
Page 11
Image 11
SPECIFICATIONS

SPECIFICATIONS

WIRING

DIAGRAM

Output Rating (BTU/Hr)

Fuel

Fuel Consumption

Gallons/Hour

Pounds/Hour

Supply Pressure To Regulator

Minimum (for purposes of

input adjustment)

Maximum

Regulator Outlet Pressure

(Factory Preset)

Manifold Pressure

Hot Air Output (CFM Approx)

Motor

Electric Input

Amperage

Ignition

Ignitor Gap (Inches)

Weight (Pounds)

Heater

Shipping

Size - L x W x H (Inches)

150,000

Propane Vapor Only

1.6

7.0

10 psi

Tank Pressure

13" WC

9.75" WC 550

3,450 RPM, 1/8 HP

120 V/60 Hz

2.2

Direct Spark, Interrupted Type

.13/.15

27

36

36 x 14.5 x 20

Thermal

Switch

Blue

Insulated

Connector

Blue

Note: Some models do not have a fuse.

Blue

 

Solenoid

 

 

 

 

 

 

Valve

 

Blue

 

Green

 

 

 

 

Safety

 

Orange

Control

 

 

 

Ignitor

G

V

VR ACR AC

Position of

 

 

 

 

 

 

Leads May

 

 

 

Vary

White

 

Black

 

 

 

Motor

 

 

 

On/Off

Switch

Power Cord 120 VAC

Black

Black White

Fuse (If Equipped)

Black

 

Relay S or 2

Black

Red

L or 1

M or 3

White

 

Green

 

Green

11

101568

Page 11
Image 11