OPERATION
8
!WARNING
Review and understand the warnings in the Safety Information Section, pages 2 and 3. They are needed to safely operate this heater. Follow all local codes when using this heater.
To Start Heater
1.Follow all installation, ventilation and safety information.
2.Locate heater on stable and level surface. Make sure strong drafts do not blow into front or rear of heater.
3.Plug power cord of heater into a
Extension Cord Size Requirement
Up to 50 feet long, use 18 AWG rated cord.
51 to 100 feet long, use 16 AWG rated cord.
101 to 200 feet long, use 14 AWG rated cord.
4.Plug extension cord into a 120 volt/60 hertz,
5.Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly,
6.Turn on/off switch to the ON position. Heater will start within twenty seconds. Note: If heater does not start, turn on/off switch to the OFF position. Wait ten seconds for safety control to reset, then try again.
To Stop Heater
1.Tightly close propane supply valve on propane tank(s). Allow heater to burn remaining fuel in hose.
2.Wait a few seconds. Heater will burn gas left in supply hoses.
3.Turn on/off switch to the OFF position.
4.Unplug heater.
101568