6. GENERATOR USE
To
prevent electrical shock from faulty appliances, the generator should be grounded.
Connect a length of heavy wire between the ground terminal and the ground source.
CAUTION :
0 Limit operation requiring maximum power to 30 minutes.
For continuous operation, do not excaad the rated power.
In either caaa, the total wattage of all appliances connected muat be considered.
l
Do not exceed the current limit apacified for any one receptacle.
l
Do not connect the generator to a household circuit. This could caueo the
damage to the generator.
1. Turn the voltage selector switch to either position.
NOTE :
If you turn the switch to 12OV you can use six receptacles for 12OV appliances.
If 12OV/24OV is selected, you can use five receptacles for 12OV and one receptacle
240V.
GROUND TERMINAL
I
VOLTAGE SELECTOR
I
14