AC Operation
VOLTAGESELECTOR SWITCH
1
ACCIRCUIT PROTEC TORS
ACCIRCUIT BREAKER
1:ExceptEM3800SX
Start the engine (see page ).
Turn the voltage selector switch to either position.
With the voltage selector switch in the ‘‘120/240V’’ position, you can
use the 120V and 120/240V receptacles simultaneously. If you are
NOT using the 120/240V receptacle, then select the ‘‘120V ONLY’’
position.
Switch the AC circuit breaker ON.
Plug in the appliance.
Be sure that all appliances are in good working order beforeconnecting them to the generator. If an appliance begins to operateabnormally, becomes sluggish, or stops suddenly, turn off the ignitionswitch lever immediately. Then disconnect the appliance and examineit for signs of malfunction.Most motorized appliances require more than their rated power for
startup.
Do not exceed the current limit specified for any one receptacle. If an
overloaded circuit causes the AC circuit breaker or AC circuit protector
to switch OFF, reduce the electrical load on the circuit, wait a few
minutes and then reset the AC circuit breaker or AC circuit protector.