5. Air cleaner
Remove the wing nut, washer and air cleaner cover.
Check the element for dirt or obstruction.
Clean the element if necessary (see page 18).
AIR CLEANER
COVER
\
AIR CLEANER
ELEMENT
6. Priming water
The pump chamber should be completely filled before operating.
CAUTION: Never attempt to operate the pump without priming water or
the pump will overheat. Extended dry operation will destroy the pump
seal. If the unit has been operated dry, stop the engine immediately and
allow the pump to cool before adding priming water.
PRIMING WATER
FILLER CAP
10 .