nDescription

This programmable thermostat can be used to control an electric heating system such as an electric baseboard heater, a radiant ceil- ing, a radiant floor, a convector, etc.

Temperature preset buttons

 

Appears when the

 

setpoint is displayed

Time and day

 

Set the day

Temperature

 

Set the time

Operating

Program the

mode icons

 

schedule

Temperature

Skip a period

preset icons

 

Select the

Heating power

indicator

operating mode

 

Periods

 

Temperature adjustment buttons

The thermostat cannot be used under the following conditions:

The resistive load is greater than 16.7 A

The resistive load is less than 2 A

The system is driven by a contactor or relay (inductive load)

The system is a central heating system

SUPPLIED PARTS:

One (1) thermostat

Two (2) 6-32 screws

Two (2) solderless connectors

oInstallation

TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK.

THE INSTALLATION MUST BE PERFORMED BY AN ELECTRI- CIAN.

All cables and connections must conform to the local electrical code.

Special CO/ALR solderless connectors must be used when connecting with aluminum conductors.

Install the thermostat onto an electrical box.

Install the thermostat about 5 feet high, on an inside wall facing the heater.

Avoid locations where there are air drafts (such as the top of a staircase or an air outlet), dead air spots (such as behind a door), or direct sunlight.

Do not install the thermostat on a wall that conceals chimney or stove pipes.

The thermostat wires are not polarized; either wire can be connected to the load or to the power supply.

08060 / TH106 / TL6061

Programmable Thermostat - Installation and User Guide

08160

TH106

TL6160

NOTE: Always keep the thermostat's vents clean and unobstructed.

n

oConnect the thermostat wires to the line wires and to the load wires using solderless connectors for copper wires.

2-wire installation

4-wire installation

pPush any excess wire back into the electrical box.

NOTE: If necessary, before re-installing the front component, configure the thermostat (see section 3).

qReturn power to heating system.

69-20241/11/061/3