nDescription
This programmable thermostat can be used to control an electric heating system such as an electric baseboard heater, a radiant ceil- ing, a radiant floor, a convector, etc.
Temperature preset buttons
| Appears when the |
| setpoint is displayed |
Time and day |
|
Set the day | Temperature |
| |
Set the time | Operating |
Program the | mode icons |
| |
schedule | Temperature |
Skip a period | preset icons |
| |
Select the | Heating power |
indicator | |
operating mode |
|
Periods |
|
Temperature adjustment buttons
The thermostat cannot be used under the following conditions:
•The resistive load is greater than 16.7 A
•The resistive load is less than 2 A
•The system is driven by a contactor or relay (inductive load)
•The system is a central heating system
SUPPLIED PARTS:
•One (1) thermostat
•Two (2)
•Two (2) solderless connectors
oInstallation
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK.
THE INSTALLATION MUST BE PERFORMED BY AN ELECTRI- CIAN.
All cables and connections must conform to the local electrical code.
Special CO/ALR solderless connectors must be used when connecting with aluminum conductors.
Install the thermostat onto an electrical box.
Install the thermostat about 5 feet high, on an inside wall facing the heater.
Avoid locations where there are air drafts (such as the top of a staircase or an air outlet), dead air spots (such as behind a door), or direct sunlight.
Do not install the thermostat on a wall that conceals chimney or stove pipes.
The thermostat wires are not polarized; either wire can be connected to the load or to the power supply.
08060 / TH106 / TL6061
Programmable Thermostat - Installation and User Guide
08160
TH106
TL6160
NOTE: Always keep the thermostat's vents clean and unobstructed.
n
oConnect the thermostat wires to the line wires and to the load wires using solderless connectors for copper wires.
pPush any excess wire back into the electrical box.
NOTE: If necessary, before
qReturn power to heating system.