SEQBLKsequence editor start command
62 code identifier for Code 39
0012 A - Code 39 sample length (11) plus CR suffix (1) = 12
41start character match for Code 39, 41h = “A”
FF termination string for first code
6A code identifier for Code 128
0013 B - Code 128 sample length (12) plus CR suffix (1) = 13
42start character match for Code 128, 42h = “B”
FF termination string for second code
69code identifier for Code 93
0012 C - Code 93 sample length (11) plus CR suffix (1) = 12
43start character match for Code 93, 43h = “C”
FF termination string for third code
Output Sequence Editor
Enter Sequence
Default Sequence
Sequence TimeoutYou may wish to set the maximum time between bar code scans in an output sequence. If that maximum time is not met, the output sequence operation is terminated. Set the length (in milliseconds) for a timeout by scanning the bar code below, then setting the timeout (from
Sequence Timeout
3 - 19