Fig. 6b
Fig. 6a

Intelli-CheckTM

FilterMonitors

This air cleaner is equipped with Intelli-Check FilterTM Monitors to serve as a convenient guideline for replacement of the pre-filter and HEPA filter based on the air cleaner’s hours of use and operating speed. This is beneficial because a filter’s life depends on the amount of air and contaminants drawn through it. Each filter bar will fill up from clean to dirty as its expected filter life is used up. Once the bar is completely full, it is time to check / replace the filter.

To move between the PRE-FILTER bar and the HEPA FILTER bar, quickly press the FILTER button (Fig. 6a).

To RESET a filter bar that appears on the display, press and hold the FILTER button for 5 seconds, or until the filter bar clears to CLEAN status (Fig. 6b).

The Intelli-CheckFilter Monitors calculate the expected filter life based on an assumed average operating time of 12 hours a day on medium speed. Therefore, it will indicate replacement of the Pre-filter in about 3 months, and the HEPA filter in about 1 year and 9 months. Depending upon your individual usage (environment, hours and speed of operation), you may need to check and replace the filters more or less frequently.

PRE Filter Life HEPA

PRE Filter Life HEPA

HowtoInstallandReplacetheFilters

INSTALL PRE-FILTER BEFORE INITIAL OPERATION. The initial

pre-filter is packaged separately to ensure its freshness. BEFORE

Fig. 7

initial operation, locate the pre-filter in the package and install per the instructions (Refer to Page 2 “Construction” section).

DISCONNECT FROM POWER SUPPLY BEFORE SERVICING.

1.Unscrew locking mechanism counter-clockwise (Fig. 7).

2.Remove Endcap and remove filter assembly from unit (Fig. 8).

3.Undo fastener(s) and remove pre-filter.

4.As needed, replace HEPA Filter (there is no orientation to filter).

5.As needed, install new pre-filter by securing it around HEPA filter with the fastener(s) provided (Fig. 9).

6.Replace endcap.

7.Insert and tighten locking mechanism clockwise.

8.Discard used filter(s).

9.Plug in and RESET appropriate filter monitor(s) per instructions below.

Press FILTER button until the PRE-FILTER or HEPA FILTER monitor you wish to reset appears on the display.

Press and hold for 5 seconds, or until the filter bar clears fully to CLEAN status.

Fig. 8

Fig. 9

Page 9
Image 9
Honeywell 17005 owner manual Intelli- CheckTM Filter Monitors, How to Install and Replace the Filters

17005 specifications

The Honeywell 17005 is a robust and versatile product that has gained a reputation for providing reliable performance in various industrial applications. Known for its advanced technologies and user-friendly design, the 17005 is particularly sought after in sectors such as manufacturing, healthcare, and building management.

One of the standout features of the Honeywell 17005 is its high level of adaptability. The device is engineered to be compatible with various software platforms, allowing for seamless integration into existing systems. This flexibility ensures that businesses can implement the 17005 without the need for extensive modifications to their infrastructure, making it a cost-effective solution for efficiency and productivity.

Another key characteristic of the Honeywell 17005 is its advanced connectivity options. The device supports multiple communication protocols, including Ethernet, Modbus, and BACnet, facilitating real-time data transfer and monitoring. This capability enhances operational visibility, allowing users to make informed decisions quickly based on accurate data.

Moreover, the Honeywell 17005 employs state-of-the-art sensing technologies to provide precise monitoring of environmental conditions. With features such as temperature and humidity sensors, the device helps maintain optimal working conditions, which can lead to increased comfort and productivity for employees. Additionally, its ability to monitor energy consumption contributes to sustainability efforts by helping organizations identify areas for energy savings.

The ergonomic design of the Honeywell 17005 further enhances its usability. Its intuitive user interface and easy-to-navigate display ensure that users can operate the device with minimal training. This focus on user experience is complemented by robust support options provided by Honeywell, including comprehensive documentation and responsive customer service.

In terms of durability, the Honeywell 17005 is built to withstand the rigors of industrial environments. Its rugged construction and resistance to dust and moisture ensure reliable operation even in challenging conditions. This reliability is a significant factor that helps businesses minimize downtime and maximize operational efficiency.

Overall, the Honeywell 17005 is a feature-rich device that combines advanced technologies with practical design elements. Its adaptability, connectivity, environmental monitoring capabilities, and user-friendly interface make it a valuable asset for any organization looking to enhance its operational effectiveness and sustainability initiatives. With such attributes, the Honeywell 17005 continues to be a preferred choice for industries worldwide, driving innovation and efficiency across various applications.