Section 5. Testing the 4500 With the 4286 Phone Module
5-3
2. Obtain phone access from the phone module. Enter the 2-digit phone
code. Enter the 4-digit system code if prompted.
3. Press # 99 on the phone keypad after the complete status announcement.
4. The 4286 will announce: “Thermostat Mode.”
The temperature setting for thermostat #1 will follow. You can change its set
point using menu selection 1 below. If thermostat #1 is in BYPASS or
CHECK, that status will be announced instead of the set point. The 4286 will
also announce whether set-back has been turned off by the user.
Menu Selections
“To change temperature, enter 1.” This selection is used to set the armed
away set-back temperature for thermostats #1 or #2 (This menu selection
will NOT be announced if the thermostat is in “CHECK or BYPASSED”)
To allow the user to change the ARMED AWAY set-back temperature
settings, the 4286 will announce the present setting in effect, and wait for
a new 2-digit temperature setting to be entered. If the current
temperature setting is acceptable to the user, the user may press the
key to advance without changing the setting.
If the number entered is outside the allowed range (45° to 99° F., 07° to
37° C), a buzzer will sound from the phone, and the temperature setting
repeated. This will continue until the number entered is within the
allowable range.
If the 4500 is BYPASSed, the user must switch the ACTIVE/BYPASS
slide switch on the 4500 front panel to the ACTIVE position, which will
then allow access through the 4286 thermostat menus.