Honeywell 5800ZBRIDGE setup guide Z-BridgeModule, Installation And Setup Guide

Models: 5800ZBRIDGE

1 4
Download 4 pages 53.21 Kb
Page 1
Image 1
5800ZBRIDGE

800-08932 5/11 Rev. A

5800ZBRIDGE

Z-Bridge Module

INSTALLATION AND SETUP GUIDE

GENERAL INFORMATION

5800ZBRIDGE is a wireless, intelligent energy management device that provides an interface between Z-Wave Modules and Honeywell LYNX Security Systems and VISTA Control Panels that are equipped with RF keypads.

Note: The 5800ZBridge is not compatible with the 5800TM or 5883H modules.

Features

Automatically set back Z-Wave enabled thermostat when security system is Armed AWAY.

Automatically turns lights off when security system is Armed AWAY.

Sends run command to Z-Wave enabled thermostat when security system is Disarmed.

Automatically turns lights on when security system is Disarmed.

Alarm Status light: Ready, Armed Away and Stay.

Will function with any Z-Wave device

MOUNTING

1.Determine the optimum mounting location taking care to avoid damp locations. To maximize the transmitter’s range, avoid mounting the device to metal objects, if possible. The module should be located a maximum of 6 feet from an unswitched 120VAC outlet.

2.Open the 5800ZBRIDGE case as shown in Figure 1.

3.Mount the 5800ZBRIDGE using the provided screws. (Refer to Figure 2)

5800Z-002-V0

Figure 1. Opening the 5800ZBRIDGE

POWER UP MODULE

1.Plug in 12VDC power supply, LED flashes ORANGE 3 times and then goes out. (Refer to Figure 2)

PROGRAMMING

Enroll 5800TM Code into Module

1.Press SW5 LEARN switch for 1 second and release. LED will begin flashing ORANGE.

2.Disarm or Arm the control panel (with 5800TM code turned on). The LED will stop flashing ORANGE and the color will follow status of the control panel.

Note: The module will time out of program mode after 3 minutes if no TM code is enrolled.

Table 1 - 5800ZBRIDGE LED Indications

Indication

Meaning

Flashing Red

Armed AWAY

Steady Red

Armed STAY

Solid Green

Ready

Flashing Orange

ALARM/Panic

Note: Following an alarm, the User Code must be entered twice and the keypad must go to ready in order for the Z-Bridge Module to release thermostat setback and/or turn on lights.

Enroll (include) Devices in Z-Wave Modules into 5800ZBRIDGE module

1.Press the corresponding switch (SW1 through 4) for 1 second and release for any combination of four Thermostats or Lights. (Refer to Figure 2)

2.The 5800ZBRIDGE LED will begin flashing Green.

3.Press button on the respective Z-Wave device to learn (include) the device. The 5800ZBRIDGE LED will stop flashing GREEN and return to status of control panel.

4.Repeat for each Z-Wave device as applicable.

Note: The module will time out of program mode after 2 minutes if no Z-Wave device in enrolled (included).

Reset 5800ZBRIDGE Module

1.Disconnect the 12VDC power supply.

2.Press and hold SW5 LEARN switch and then plug in 12VDC power supply. LED flashes Orange 5 times and then goes out.

3.Release switch SW5. TM code has been deleted and 5800ZBRIDGE has been deleted (excluded) from the Z-Wave network.

- 1 -

Page 1
Image 1
Honeywell 5800ZBRIDGE setup guide Z-BridgeModule, Installation And Setup Guide