INSTALLATION
CABLE INSTALLATION (INTERFACE SPECIFIC)
RS232
1. | Turn off the host system. |
|
2. | Connect the keyed VLink cable to |
|
| the |
|
| the only circular keyed jack located |
|
| on the bottom of the 7820 (see |
|
| figure 8). |
|
3. | Connect the other end of the VLink |
|
| cable to the host. |
|
| Before continuing, verify the VLink |
|
| cable is connected to the |
|
| appropriate interface jack on the |
|
| scanner. An incorrect cable |
|
| connection can cause |
|
| communication problems or |
|
| potential damage to the scanner. |
|
4. | Connect the external power supply |
|
| to the power jack on the scanner. |
|
5. | Check the AC input requirements of | Figure 8. RS232 Interface |
|
the power supply to make sure the voltage matches the AC outlet.
6.Connect AC power to the transformer. The outlet should be near the equipment and easily accessible.
7.Scan the Recall Defaults bar code to configure the 7820 for RS232 communication.
8.Turn on the host system.
9.Snap on the cable cover.
Recall Defaults
³ 9 9 9 9 9 8

See SELV Power caution statement located on page 11 of this manual.
15