![08160](/images/new-backgrounds/174312/1743121x1.webp)
08160
TH106
TL6160
Time and day
Set the day
Set the time
Program the schedule
Skip a period
Select the mode of operation
Indicates the heating power
Temperature preset buttons
Indicates that the temperature setpoint
is displayed
Indicates that the settings are locked
Temperature
Indicates the current mode of operation
Temperature preset icon
| Indicates that the | |
| thermostat is configured | |
| for a | |
| Indicates the current | |
| period (appears in | |
Temperature | automatic mode only) | |
Indicates that the ther- | ||
adjustment | ||
buttons | mostat is without power * |
NOTE: Always keep the thermostat's vents clean and unobstructed.
n
oConnect the thermostat wires to the line wires and to the load wires using solderless connectors for copper wires.
*LP appears only for the first two minutes when the thermostat is without power. This can occur during a power outage or when the thermal protection device inside the base- board heater is opened.
nDescription
This programmable thermostat can be used to control an electric heating system such as an electric baseboard heater, a radiant ceil- ing, a radiant floor, a convector or a
The thermostat cannot be used with:
•a resistive load over 16.7 A
•a resistive load under 2 A
•a system driven by a contactor or relay (inductive load)
•a central heating system
SUPPLIED PARTS:
•One (1) thermostat
•Two (2)
•Two (2) solderless connectors
oInstallation
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. THE INSTAL- LATION MUST BE PERFORMED BY AN ELECTRICIAN.
All cables and connections must conform to the local electrical code.
Special CO/ALR solderless connectors must be used when con- necting with aluminum conductors.
Install the thermostat onto an electrical box.
Install the thermostat about 5 feet high, on an inside wall facing the heater.
Avoid locations where there are air drafts (such as the top of a staircase or an air outlet), dead air spots (such as behind a door), or direct sunlight.
Do not install the thermostat on a wall that conceals chimney or stove pipes.
The thermostat wires are not polarized; either wire can be con- nected to the load or to the power supply.
2-wire installation
pPush any excess wire back into the electrical box.
NOTE: If necessary, before
qReturn power to heating system.
08060 / TH106 / TL6061 | 1/4 | ||
Programmable Thermostat - Installation and User Guide |
|
|
|