Symptom

What if something happens to my heating system? How can I check that the CM61NG is working?

See the troubleshooting guide below. If you need assistance after this call your installer.

CM61NG Trouble-Shooting Guide

Symptom

Possible Cause

Remedy

 

 

 

Blank display

No batteries

Check that the batteries are in the battery compartment and that the

 

 

paper tab has been pulled out

 

Wrong battery orientation

Check that the batteries have been installed in the correct orientation

 

Exhausted batteries

Replace batteries

 

 

 

Display shows flashing ‘battery’

Improper battery compartment insertion

Remove battery compartment and re-insert

symbol

 

 

 

Batteries need replacing

Change batteries as described previously

 

 

 

Display shows ‘flame’ symbol but

The heating is not required at this

The heat demand is sent to the relay box as a value between 0-100%.

heating does not switch on

moment

The relay box will adjust the boiler on time to meet this requirement.

 

 

That is why the heating will be off sometimes even if the ‘flame’

 

 

symbol is displayed. To check if RF system is communicating properly

 

 

press the TEMPerature UP button to increase the set temperature a

 

 

few degrees above the current temperature. The heating should come

 

 

on after a few seconds

 

 

 

Display works but heating does not

Boiler switched off

Switch the boiler on

switch on (HC60NG LEDs are off or

 

 

green one is on)

Wrong electrical connection

Call electrical installer to check the boiler and relay box power supply

 

 

 

as well as the connection between the boiler and the relay box

 

 

 

HC60NG red LED is constantly on or

RF communication lost due to the

Hook the room unit back on the wall bracket or replace the room unit

flashing

wrong location of the room unit

on the table stand to the position where RF communication was

 

 

reliable.

 

RF communication fault

Call installer

 

 

NOTE: You can control the boiler manually when the RF communica-

 

 

tion is lost:

 

 

Press the HC60NG push button to switch the boiler on and off. When

 

 

the green LED is on – the boiler is on.

 

 

 

Heating switches on or off too slowly

CM61NG not set correctly for your

Call installer

or too quickly

system

 

 

 

 

Temperature swings between too hot

CM61NG not set correctly for your

Call installer

and too cold

system

 

Display show ‘spanner’ symbol

Fault in the CM61NG

Remove the battery compartment and re-insert it. If the ‘spanner’

 

 

symbol does not clear itself in a few minutes call the installer

 

 

 

Warning.

This product and its associated documentation and packaging are protected by various intellectual property rights belonging to Honeywell Inc and its subsidiaries and existing under the laws of the UK and other countries. These intellectual and property rights may include patent applications, registered designs, unregistered designs, registered trade marks, unregistered trade marks and copyrights and also include the following UK registra- tion rights:

UK patent application number 98062207.8

UK registered design numbers 2073334, 2073340 and 2073343.

 

honeywell

 

 

Honeywell Control Systems Ltd.

www.honeywell.com/uk/homes.htm

Arlington Business Park

 

Bracknell, Berkshire RG12 1EB

 

Tel: 01344 656000

 

honeywell

RF Programmable Thermostat

What is an RF Programmable Thermostat?

A Honeywell Radio Frequency (RF) programmable thermostat is a thermostat that controls your heating system so that you can have comfortable temperatures when you are at home and energy savings when you are out. With RF communication there is no need to provide a wired connection between thermostat and boiler. The Possible CauseCM61NG can therefore be installed without disrupting your room decor. These instructions explain how to program and operate your RemedyCM61NG to get the most comfort at the least cost.

What will the CM61NG Programmable Thermo- stat do for me?

Wireless connection to the boiler allows you to mount the

honeywellCM61NG in your room without disrupting the decor

Armchair programming lets you set up your Manual backgroundCM61NG while resting comfortably in your armchair

Optimum Start means that the Manual backgroundCM61NG will switch on your heating system so that your desired comfort temperature is

reached at the programmed time, thus avoiding unnecessary boiler firing

Attractive slim styling compatible with any room decor

6 daily independent temperature levels let you set any 6 temperatures from 5 to 30°C to match your daily lifestyle

Holiday button saves energy by letting you reduce the tempera- ture for 1 to 99 days while you are on holiday, returning to normal

operation on the day you return

Memory holds the user program indefinitely so that it is never lost even if you take the batteries out

What is Optimum Start?

Instead of switching on the heating at the set time every day, the Manual backgroundCM61NG will delay the start time to the latest possible moment, so

that unnecessary heating is avoided. All you have to do is set the time when you want comfort temperature and the Manual backgroundCM61NG will then decide when to turn the heating on, thereby ensuring your comfort.