CM67 CHRONOTHERM
INSTALLER SET-UP
To enter the installer
a)Set the program slider to OFF.
b)Press and hold Info i button and press PROG 3,4 together.
c)The unit will display the first parameter of the installer parameter group category 1 (from n.1 to n.5).
d)Press TEMP or to change factory setting. The display will flash indicating that a change has been made.
e)Press INFO i button to confirm the change. The display will stop flashing.
f)Press + or - to go to next parameter.
g)Press PROG 2 button to go to Installer parameter group category 2 (from parameter n.6 to parameter n.16).
h)To exit installer mode move the slider in MAN or AUTO position.
In Installer set up we can :
❑
❑Enable special features
❑Establish support for Optional Accessories
Installer
(Press + or - to change) e.g. 1 = Optimisation
Installer
Selected
Abbreviated
e.g. OP = Optimisation
1
Factory Setting or New Choice
Press TEMP ▲ or ▼to change e.g. O = Optimisation disabled 1 = Optimisation enabled
Specific Applications | Setting | What do you need to change ? | |||
|
| Cycle/ | Minimum | Note : | |
|
| Hour | ON time | a. To change Cycle/Hour, please go to parameter n. 9 in the | |
|
|
| (in minutes) |
| installer |
|
|
|
| b. To change Minimum ON Time, please go to parameter n. 2 in | |
|
|
|
|
| the installer |
|
|
|
|
| |
Heating | Gas Boilers | 6 | 1 | No action required | |
| (<30KW) |
|
|
|
|
|
|
|
|
|
|
| Oil Boiler | 3 | 4 | 1. | Set Minimum ON Time to 4 minutes. |
|
|
|
| 2. | Set Cycle/Hour to 3. |
|
|
|
|
| |
| Thermal | 12 | 1 | Set Cycle/Hour to 12. | |
| Actuator |
|
|
|
|
|
|
|
|
| |
| Zone valve | 6 | 1 | No action required. | |
|
|
|
|
|
|
| Electric heating | 12 | 1 | 1. | Configure the Chronotherm for electric heating (set parameter |
| (for applications |
|
|
| n.7 in the installer set up mode to 1). |
| <8A) |
|
| 2. | Set Cycle/Hour to 12. |
|
|
|
|
|
|
|
|
|
|
|
|
Air |
|
|
| 1. | For cooling application only, set the Chronotherm to cooling |
conditioning |
|
|
|
| (set parameter n.6 in the installer |
|
|
|
| 2. | For heat/ cool application, set the Chronotherm accordingly to |
|
|
|
|
| required mode of operation |
|
|
|
|
| winter = heating |
|
|
|
|
| summer = cooling |
|
|
|
| by changing parameter n.6 in the installer | |
|
|
|
| the | |
|
|
|
|
|
|
| Heat Pump/ | 3 | 4 | 1. | Set Minimum ON Time to 4 minutes . |
| Air conditioner |
|
| 2. | Set Cycle/Hour to 3. |
|
|
|
|
|
|
|
|
|
|
|
|
3 | EN0R 8498 R2 11/98 |