Honeywell CM67 Installer Set-Up, In Installer set up we can, Specific Applications, Setting

Models: CM67

1 7
Download 7 pages 22.98 Kb
Page 3
Image 3
INSTALLER SET-UP

CM67 CHRONOTHERM

INSTALLER SET-UP

To enter the installer set-up mode :

a)Set the program slider to OFF.

b)Press and hold Info i button and press PROG 3,4 together.

c)The unit will display the first parameter of the installer parameter group category 1 (from n.1 to n.5).

d)Press TEMP In Installer set up we can : or Specific Applicationsto change factory setting. The display will flash indicating that a change has been made.

e)Press INFO i button to confirm the change. The display will stop flashing.

f)Press Setting + or - to go to next parameter.

g)Press PROG 2 button to go to Installer parameter group category 2 (from parameter n.6 to parameter n.16).

h)To exit installer mode move the slider in MAN or AUTO position.

In Installer set up we can :

Set-up specific applications

Enable special features

Establish support for Optional Accessories

Installer Set-up Number

(Press What do you need to change ?+ or - to change) e.g. 1 = Optimisation

Installer Set-Up Mode

Selected

Abbreviated Set-Up Description

e.g. OP = Optimisation

1

Factory Setting or New Choice

Press TEMP or to change e.g. O = Optimisation disabled 1 = Optimisation enabled

Specific Applications

Setting

What do you need to change ?

 

 

Cycle/

Minimum

Note :

 

 

Hour

ON time

a. To change Cycle/Hour, please go to parameter n. 9 in the

 

 

 

(in minutes)

 

installer set-up mode.

 

 

 

 

b. To change Minimum ON Time, please go to parameter n. 2 in

 

 

 

 

 

the installer set-up mode.

 

 

 

 

 

Heating

Gas Boilers

6

1

No action required

 

(<30KW)

 

 

 

 

 

 

 

 

 

 

 

Oil Boiler

3

4

1.

Set Minimum ON Time to 4 minutes.

 

 

 

 

2.

Set Cycle/Hour to 3.

 

 

 

 

 

 

Thermal

12

1

Set Cycle/Hour to 12.

 

Actuator

 

 

 

 

 

 

 

 

 

 

Zone valve

6

1

No action required.

 

 

 

 

 

 

 

Electric heating

12

1

1.

Configure the Chronotherm for electric heating (set parameter

 

(for applications

 

 

 

n.7 in the installer set up mode to 1).

 

<8A)

 

 

2.

Set Cycle/Hour to 12.

 

 

 

 

 

 

 

 

 

 

 

 

Air

 

 

 

1.

For cooling application only, set the Chronotherm to cooling

conditioning

 

 

 

 

(set parameter n.6 in the installer set-up mode to 0)

 

 

 

 

2.

For heat/ cool application, set the Chronotherm accordingly to

 

 

 

 

 

required mode of operation

 

 

 

 

 

winter = heating

 

 

 

 

 

summer = cooling

 

 

 

 

by changing parameter n.6 in the installer set-up mode. Explain to

 

 

 

 

the end-user how to implement the change-over.

 

 

 

 

 

 

 

Heat Pump/

3

4

1.

Set Minimum ON Time to 4 minutes .

 

Air conditioner

 

 

2.

Set Cycle/Hour to 3.

 

 

 

 

 

 

 

 

 

 

 

 

3

EN0R 8498 R2 11/98