DIMENSIONS

CM67 CHRONOTHERM

DIMENSIONS

INSTALLATION

LOCATION

The CM67 Chronotherm is the temperature control element in the heating/cooling system and MUST be located in a position with good air circulation at average room temperature on an inside wall 1.5 metres above the floor level. Do not position the CM67 Chronotherm near sources of heat (radiators, hot air vents, TV or lights), near doors or windows, or in direct sunlight.

MOUNTING

The CM67 Chronotherm can be mounted directly on the wall surface or on an electrical wallbox.

WIRING

The CM67 Chronotherm is designed for fixed wiring only and must be installed in accordance with latest l.E.E. regulations. Ensure the wiring connection to the supply is via a fuse rated at no more than 8 amps and a Class "A" switch (having contact separation of at least 3 mm in all poles).

IMPORTANT

1. The installer must be a trained service engineer

2. Disconnect the power supply before beginning installation