TrueDRY™ DR120
Ventilating Dehumidification System
DR120 Capacities and Performance
Part Number: | DR120A2000 |
|
|
Blower: | 350 CFM @ 0.0 in. WG |
| 210 CFM @ 0.4 in. WG |
|
|
Supply Voltage: | 120 VAC; 60 Hz. |
|
|
Amps: | 8.1 A |
|
|
Power transformer |
|
to R/C terminals: | 24 VAC, 0.85A |
Energy | 2.69 liters (5.7 pints) per |
performance: | kilowatt hour (KWH) |
Refrigerant: | |
| |
Operating Temp Range | |
(outside cabinet): | 34 – 135 ºF (1.1 – 57.2 ºC) |
Capacity:
65 pints/day (60 ºF [15.6 ºC], 60 %RH)
91 pints/day (70 ºF [21.1 ºC], 60 %RH)
120 pints/day (80 ºF [26.7 ºC], 60 %RH)
Coverage: | Up to 3500 sq. ft. |
|
|
Duct Connections: | 6 in. Supply Inlet |
| 10 in. Round Inlet |
| 10 in. Round Outlet |
| (ABS Plastic) |
|
|
Filter Efficiency: | Standard |
SPECIFICATION DATA
(365) | (81) | (656) | (81) |
21 |
|
| |
(533) |
|
| |
(492) |
|
| |
|
|
|
Drain Connection: 3/4 in. threaded female NPT, |
with attached 3/4 in. threaded |
Fig. 1. Dimensions in in. (mm).
M33292
| male NPT |
|
|
| |
Dimensions (See Fig. 1): |
| |
Width: |
| |
Height: |
| |
Length: | ||
| ||
Weight: | 90 lbs (40.8 Kg) | |
Shipping Specs |
|
|
Width: |
| |
Height: |
| |
Length: |
| |
Weight: | 101 lbs (45.8 Kg) | |
|
|
|
Optional Parts |
|
|
Replacement Filter |
| |
Motorized Ventilation Damper | EARD6 | |
10” Backdraft Damper |
| SPRD10 |
Compressor Relay, 24 VAC, 30 A | ||
Compressor Run Capacitor | ||
10” Duct Collar |
| |
Fan Assembly |
| |
Capacitor - Fan |
| |
Fan Relay, SPDT, 24 VAC, 15A | ||
Transformer 120/24 VAC, 40 VA | ||
Defrost Thermostat |
| |
Leveling Foot |
|
ETL Listed. Energy Star Rated. Conforms to UL Std. 474.
For more information call
Honeywell TrueDRY
Dehumidification
The Honeywell TrueDRY DR120 dehumidifier utilizes refrigeration and inter- nal air circulation to cool the incoming air stream below its dew point. Water condenses and drains off the coil, sending drier air back into the house.
•Can remove up to 120 pints/day of moisture.
•Energy Star rated
•Electrocoating reduces coil corrosion and helps prevent refrigerant leaks
•Top or side ducted exhaust
•Reduced noise during operation
•MERV 11 air filtration
Ventilation
The Honeywell TrueDRY DR120 has a separate control for ventilation, so the powerful onboard blower can be used to efficiently bring fresh air into the house even when dehumidification is not needed. The TrueDRY DR120 has a 6” supply side damper that can be used to duct in air from the out- side, or closed if not needed.
Simplified Wiring
The Honeywell TrueDRY DR120 dehumidifiers can be controlled by a variety of
The TrueDRY DR120 allows the use of a 24V normally closed float switch or water sensor to simplify installation in a drain pan. This will allow the exter- nal float switch to kill power to the compressor in the event of water block- age.