Honeywell DR120 Installation Recommendations and Options, Dedicated Return to Main Supply

Models: DR120

1 2
Download 2 pages 44.7 Kb
Page 2
Image 2
Installation Recommendations and Options

Installation Recommendations and Options

Dedicated Return to Main Supply

A

AIR HANDLER

 

RETURN

SUPPLY

 

TrueDRY

 

 

SEPARATE

 

 

RETURN

 

 

 

(OPTIONAL)

 

BACKDRAFT

GRAVITY DAMPER

 

DAMPER

M33150

Ideal when…

Access to a dedicated central return for

TrueDRY DR65 is available.

Combined with A/C operation; requires backdraft damper on the exhaust port to minimize backdraft when TrueDRY DR65 is not on but A/C is.

Providing dry air to a specific area with an optional 20% open gravity damper on TrueDRY DR65 supply.

B

C

Main Return to Main Supply

AIR HANDLER

RETURN

SUPPLY

 

BACKDRAFT

TrueDRY

DAMPER

 

M27324

Main Return to Main Return

AIR HANDLER

RETURN

SUPPLY

TrueDRY

M27325

 

Ideal when…

Running TrueDRY DR65 when not running A/C. Requires damper on the exhaust port to minimize backdraft when TrueDRY DR65 is not on but A/C is.

Access to a dedicated central return for

TrueDRY DR65 is not available.

System fan should run with dehumidifier for best results.

Ideal when…

Running TrueDRY DR65 with A/C operation.

System fan must run with dehumidifier.

Minimizing discharge air temperature

(DAT) increase is preferred.

Access to a dedicated central return for

TrueDRY DR65 is not available.

Dedicated Return to Main Return

D

Ideal when…

 

TrueDRY

• TrueDRY DR65 will not be ducted to a

SEPARATE

forced air HVAC system.

 

RETURN

 

 

SUPPLY

 

M33152

Automation and Control Solutions

Honeywell International Inc.

1985 Douglas Drive North

Golden Valley, MN 55422

http://customer.honeywell.com

® U.S. Registered Trademark.

© 2012 Honeywell International Inc.

68-3088-01 M.S. 03-12

Printed in U.S.A.

Page 2
Image 2
Honeywell DR120 Installation Recommendations and Options, Dedicated Return to Main Supply, Main Return to Main Supply