Indoor Pendant

HD6 SERIES

SPECIFICATIONS

Indoor Pendant

Electrical

 

 

 

Environmental

 

Input Voltage

24

VAC @ 50/60Hz

 

Operating

32°F to 104°F

Input Tolerance

24

VAC ± 20%

 

Temperature

(0°C to 40°)

 

 

 

 

 

 

Power Consumption

22

W @ 24 VAC

 

Regulations

 

 

 

 

 

 

FCC: Part 15

Mechanical

 

 

 

 

 

 

 

 

Emissions

Class A

 

Housing: 7.25" H x 8.98" Dia

 

 

 

CE: EN50081-1

Dimensions

Lower Dome: 6.75" Dia

 

 

 

Immunity

CE: EN50082-1

 

Trim Ring: 6.875" Dia

 

Weight

6.6 lbs.

 

 

 

 

Top, inner: Steel Bottom: Vacuum

 

 

 

Construction

formed, optically graded acrylic

 

Weather

Electrical

Input

Voltage

Input Tolerance

Power

PTZ: 24 VAC @ 50/60Hz Heater/Blower 24 VAC

@50/60Hz 24 VAC ± 20%

PTZ: 22 W @ 24 VAC Heater/Blower 96 W

Pressurised

Electrical

Input

PTZ: 24

VAC @ 50/60Hz

Voltage

Heater/Blower 24 VAC @ 50/60Hz

 

 

Input Tolerance

24 VAC ± 20%

 

 

 

Power

PTZ: 22

W @ 24 VAC

Consumption

Heater/Blower 96 W @ 24 VAC

 

 

 

Weather

Consumption

Mechanical

Dimensions

Weight

Construction

Environmental

Operating Temperature

Regulations

@ 24 VAC

Housing:

15.85"H x 12.29" Dia

Lower Dome: 9.50" Dia

15 lbs. (6.8 kg)

Top, inner: Steel

Top, outer: White reflective acrylic Bottom: Vacuum formed, optically graded acrylic

-50°F to 122°F (-45°C to 50°C) (maintained by heater/blower)

Mechanical

Dimensions

Weight

Construction

Interior Pressurization

Housing: 16.31"H x 12.41" Dia

Lower Dome: 9.50" Dia 17 lbs. (7.7 kg)

Top, inner: Steel

Top, outer: White reflective acrylic

Bottom: Vacuum formed, optically graded acrylic

Sealing flange: 1/2" thick aluminum casting with O-ring seals Bottom dome: compresses O-rings

Dual Schraeder Valves for purging and pressurisation. Single Over Pressure valve – factory set @

7-10 lbs. Recommended: Dry nitrogen gas for pressurisation only. Optional: Recharge kit model AVN001NRK

Pressurised

Emissions

Immunity

FCC: Part 15 Class A

CE: EN50081-1

CE: EN50082-1

Environmental

Operating

-50°F to 122°F (-45°C to 50°C)

Temperature

(maintained by heater/blower)

 

 

Regulations

 

Emissions

FCC: Part 15 Class A

CE: EN50081-1

 

Immunity

CE: EN50082-1