MAINTENANCE
Maintenance Schedule
Periodic maintenance and adjustment is necessary to keep generator in good operating condition. Perform service and inspection at intervals shown in Generator Maintenance Schedule (Table 2).
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home | Only use OUTSIDE and far |
or garage, EVEN IF doors | away from windows, doors, and |
and windows are open. | vents. |
•Shut off engine before performing any maintenance. If engine must be run, be sure area is well ventilated.
Accidental starting of generator can cause severe injury or death. Before performing maintenance, disconnect spark plug cap from spark plug. Also disconnect both starting battery cables. Remove the negative
Improper maintenance, or failure to correct a problem before operation, can cause a malfunction in which you can be seriously hurt or killed. Always follow inspection and maintenance recommendations and schedules in this owner's manual.
The maintenance schedule applies to normal operating con- ditions. If you operate generator under severe conditions, such as sustained
|
|
|
| FREQUENCY* |
|
|
MAINTENANCE TASK | Before each | First month or |
| Every 3 | Every 6 | Every year or |
| 20 hours of |
| months or 50 | months or 100 | 200 hours of | |
| use |
| ||||
| use |
| hours of use | hours of use | use | |
|
|
| ||||
Check engine oil level | X |
|
|
|
|
|
Inspect for/clean debris | X |
|
|
|
|
|
Check air cleaner | X |
|
|
|
|
|
Clean air cleaner |
|
|
| X† |
|
|
Change engine oil |
| X |
|
| X |
|
Clean fuel sediment cup |
|
|
|
| X |
|
Check/clean spark plug |
|
|
|
| X |
|
Clean spark arrestor |
|
|
|
| X |
|
Check/adjust valve clearance |
|
|
|
|
| X‡ |
Clean fuel tank and strainer |
|
|
|
|
| X‡ |
Check fuel line | Every 2 years (replace if necessary)‡ |
|
|
|
TABLE 2. Generator Maintenance Schedule
*Perform at every indicated month or operating hour interval, whichever comes first.
† Clean more often when using generator in dusty areas.
‡ It is recommended that this maintenance task be performed by a service dealer.
HW5500/5500E Portable Generator Owner’s Manual | www.honeywellgenerators.com | 19 |