INSTALLATION

EAS Deactivation

SW1 and SW2 are the switch banks inside the Checkpoint Device that set the deactivation range. The following is a list of Checkpoint recommended switch bank settings.

Checkpoint Recommended Switch Bank Settings

For RS232 and IBM

SW1

 

SW2

 

Switch 1 and 6

ON

Switch 1 and 6

ON

Switch 2, 3, 4, and 5

OFF

Switch 2, 3, 4, and 5

OFF

Checkpoint Recommended Switch Bank Settings

For USB

SW1

 

SW2

 

Switch 1

ON

Switch 1

ON

Switch 2, 3, 4, 5, and 6

OFF

Switch 2, 3, 4, 5, and 6

OFF

All Fusion models equipped with EAS capabilities have an EAS designation in their model numbers. The cable supplied with these units will have additional wires for connection to the Checkpoint Device.

Figure 12. EAS Cable

Figure 13 shows the location of the EAS deactivation area for Fusion.

It is important to pass the entire tag through this area to deactivate the security tag.

Figure 13. EAS Deactivation Area

12