69-1726—1 32
Step 11. Configure Installer Setup (Cont)
13. If you do not have a number 0190 on the left side of
your display, go to the next page.
14. If you have a number 0190 on the left side of your display, press the Up or Down arrow to select your setting for Installer Setup Number 0190.15. After you select your setting, press the Next button
to go to the next Installer Setup Number.
M22310
0190 Heat Pump
Changeover
Valve
0 - Changeover Valve in Cooling --
Use this setting if you connected a
wire labeled O to the O/B terminal.
1 - Changeover Valve in Heating --
Use this setting if you connected a
wire labeled B to the O/B terminal.
UP
ARROW
DOWN
ARROW
SETTING
ADVANCE TO
NEXT INSTALLER
SETUP
PRESS TO EXIT
INSTALLER SETUP
GOES BACK
TO LAST
INSTALLER
SETUP
C
l
ock
More
Done
Next
Go Back
INSTALLER
SETUP NUMBER
P
e
ri
od
Wa
k
e
L
ea
v
e
Installer
Setup
Number
Installer
Setup
Name
(Select Your Setting)
Settings