69-1725-1 32
Step 11. Configure Installer Setup (Cont)
16. If you do not have a number 0240 on the left side of your
display, go to the next page.
17. If you have a number 0240 on the left side of your display, press the Up or Down arrow to select your setting for Installer Setup Number 0240.18. After you select your setting, press the Up arrow key to go to
the next Installer Setup Number.
M22342
0240
UP
ARROW
DOWN
ARROW
SETTING
PRE
SS
T
O
EXIT
IN
S
TALLER
S
ET
UP
Installer
Setup
Number
Installer
Setup
Name
(Select Your Setting)
Settings
D
O
N
E
INSTALLER
SETUP
NUMBER
UP
ARROW
Heating
Cycle
Rate
5 - Gas or Oil Furnace (less than
90% efficient).
9 - Electric Furnace.
3 - Gas or Oil Hot Water, Gas 90%+
High-Efficiency Furnace.
1 - Gas or Oil Steam, Gas or Oil
Gravity.