B.2 International Electrotechnical Commission (IEC) Classification of Hazardous Locations, Continued

Certification and

 

 

Conformity Details,

Table B-4

Standards Australia (LOSC) Certification

continued

 

 

 

Code

Description

 

 

 

 

4H

Intrinsically Safe Ex ia IIC T4 Class I Zone 0.

 

 

Flameproof Ex d IIC T6 Class I Zone 1

 

 

Non-Sparking Apparatus - Type of Protection ‘n’ Ex n IIC T6

 

 

Class I Zone 2

 

 

 

LOSC Intrinsic Safety Parameters (1)

Ui =

42.4 V

 

 

 

 

Ii =

225 mA

 

 

 

 

Pi =

1.2 W

 

 

 

 

Ci =

4.2 nF

 

 

 

 

Li =

0

With no integral indicator, or with

 

 

integral Smart Meter, option SM.

 

 

 

Li =

150 H

With Analog Meter, option ME.

(1)Install in accordance with Honeywell drawing 51204309.

Table B-5

Zone 2 (Europe) Declaration of Conformity

 

 

 

 

 

 

 

 

 

Code

 

Description

 

 

 

 

 

 

 

 

 

3N

 

Electrical Apparatus With Type of Protection “n” per IEC 79-

 

 

 

 

 

15. IP 66/67.

 

 

 

 

 

Ex II 3 GD T(1) X (Council Directive 94/9/EC) 40 Ta 93°C.

 

 

 

 

 

 

 

 

 

 

 

Zone 2 Parameters

 

 

 

 

 

 

 

 

 

 

 

Ui 42 V

 

 

 

 

 

Ii 22 mA

 

 

 

 

 

Temp. Code (1) T4 at Ta 93°C Maximum Ambient

 

 

 

 

 

Temp. Code (1) T5 at Ta 80°C Maximum Ambient

 

 

 

 

 

Temp. Code (1) T6 at Ta 65°C Maximum Ambient

 

 

 

 

 

 

 

92

ST 3000 Release 300 Installation Guide

2/05