T8775A,C THE DIGITAL ROUND™ NON-PROGRAMMABLE THERMOSTATS

 

 

(T8775C ONLY)

 

(T8775C ONLY)

 

SELECTS

 

SELECTS

 

ON/AUTO

 

COOL/OFF/HEAT

 

 

 

 

ROOM

SHOWS THAT THE

 

 

SET

 

 

CURRENT ROOM

 

 

 

 

 

 

TEMPERATURE IS

 

 

 

DISPLAYED.

 

 

 

SHOWS THAT THE

 

 

 

CURRENT TEMPERATURE

DISPLAYS ROOM

 

SETPOINT IS DISPLAYED.

 

 

 

OR SET TEMPERATURE

DISPLAYS AND ADJUSTS

 

 

 

 

TEMPERATURE SETPOINT/TURNS

 

 

BACKLIGHT ON

M19520

Fig. 10. T8775 Thermostat (features and operation).

SYSTEM Switch

Heat:

The thermostat controls the heating

Off:

system.

Both heating and cooling systems are off.

Cool:

The thermostat controls the cooling

 

system.

FAN Switch

Auto: The fan only runs with the heating and cooling system.

On: The fan runs continuously. Use for improved air circulation.

CHECKOUT

NOTE: Temperature setpoint range is 40°F to 90°F (4°C to 32°C) in heating and 45°F to 99°F

(7°C to 37°C) in cooling.

Heating

1.Slide the SYSTEM switch to Heat and the FAN switch to Auto (T8775C only).

2.Raise the temperature setpoint several degrees above the room temperature.

3.A flame will appear in the display and the heat should turn on.

4.Lower the temperature setpoint below the room temperature.

5.The flame will disappear from the display and the heat should turn off.

Cooling (T8775C only)

CAUTION

Low Temperature Hazard. Operating at too low of an outdoor temperature may cause compressor damage.

Do not operate cooling if outdoor temperature is below 50°F (10°C). Refer to manufacturer’s recommendations.

NOTE: If a call for cooling is made before the com- pressor has been off for five minutes, or if a power interruption occurs while the com- pressor is running, the thermostat will go into a five-minute delay to protect the com- pressor. The snowflake will flash during this delay.

1.Slide the SYSTEM switch to Cool and the FAN switch to Auto.

2.Lower the temperature setpoint several degrees below the room temperature.

3.After approximately five minutes, the thermo-

stat will display a solid snowflake

and the

cooling should turn on.

 

4.Raise the temperature setpoint above the room temperature.

5. The snowflake will disappear from the dis- play and the cooling should turn off.

Fan

1.Slide the SYSTEM switch to Off and the FAN switch to On. The fan should run continuously.

2.Slide the FAN switch to Auto. The fan should turn off.

Automation and Control Solutions

Honeywell International Inc.

Honeywell Limited-Honeywell Limitée

1985 Douglas Drive North

35 Dynamic Drive

Golden Valley, MN 55422

Scarborough, Ontario

 

M1V 4Z9

69-1677EF J.S. 6-03

Printed in Hungary

www.honeywell.com/yourhome

Page 4
Image 4
Honeywell T8775A installation instructions Checkout, Heating, Cooling T8775C only, Fan