VISIONPRO® IAQ TOTAL HOME COMFORT SYSTEM
17 68-0287—1
500
USU
Furnace Filter
Change
Reminder
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
E
Disabled
10 R.T. Days
30 R.T. Days
60 R.T. Days
90 R.T. Days
120 R.T Days
180 R.T. Days
270 R.T. Days
365 R.T. Days
30 C Days
60 C Days
90 C Days
120 C Days
180 C Days
365 C Days
Auto Discover
502 Furnace filter
reminder run time
equipment counts
0
1
Counts runtime Heat and Cool
Counts runtime Cool only
510
USU
Humidifier Pad
Replacement
Reminder
0
1
2
3
E
Disabled
90 C Days or 30 R.T. Days
180 C Days or 60 R.T. Days
365 C Days or 90 R.T. Days
Auto Discover
Display will show Calendar Days if ISU372 = 0; Run
Time Days if ISU372 = 1 or 3.
520
USU
UV Lamp
Replacement
Reminder
0
1
2
E
Disabled
365 Days
730 Days (2 years)
Auto Discover
530
USU
Adaptive
Intelligent
Recovery
0
1
Conventional
Adaptive
See Temperature Recovery on page31.
540
USU
Number of
Periods
2
4
2 Periods
4 Periods
2 periods = Wake and Sleep.
4 periods = Wake, Leave, Return, and Sleep.
580 Min Compressor
Off Time
0
1
2
3
4
5
Off
1 minute
2 minutes
3 minutes
4 minutes
5 minutes
600 Heat Temp
Range Stops
40-90 40°F–90°F (Show 1/2 degree C)
Default = 90°F
610 Cool Temp
Range Stops
60-99 60°F–99°F (Show 1/2 degree C)
Default = 60°F
640
USU
Clock Format 12
24
12 Hour
24 Hour
650 Extended Fan on
time Heat (Blower
Off Delay Heat)
0
30
60
90
120
Off
30 seconds
60 seconds
90 seconds
120 seconds
660 Extended Fan on
time Cool (Blower
Off Delay Heat)
0
30
60
90
120
Off
30 seconds
60 seconds
90 Seconds
120 Seconds
This can be used to remove condensation from A-coil;
however, could re-introduce humidity into the living
space.
670
USU
Keypad Lockout 0
1
2
Unlocked
Partial Locked
Full Locked
680 Temp Control
Heat
1
2
3
Less Aggressive temp control (may cause temp
undershoot)
Standard (recommended)
More Aggressive temp control (may cause temp
overshoot)
690 Temp Control
Cool
1
2
3
Less Aggressive temp control (may cause temp
undershoot)
Standard (recommended)
More Aggressive temp control (may cause temp
overshoot)
Table 3. Installer Setup Menu. (Continued)
ISU
Parameter
Number
Installer Setup
Name
Settings
(Factory Defaults Shown in Bold) Notes