System Installation Guide
14
69-2490 —03
Prestige THX9321 or EIM: Using universal relays to control heating or cooling

Poweringuniversalrelaywithseparate

heatingtransformer(THX9321shown)

Poweringuniversalrelaywithsystem

transformer(THX9321shown)

1
2
3

U1/U2/U3 terminals are normally open dry contacts when set up for a stage of heating or cooling.

You must install a field jumper if the stage of heating or cooling is powered by system transformer. Do NOT install a field

jumper if the stage of heating has its own transformer.

U1/U2/U3 terminals are assigned to a stage of heating or cooling in the Installer Setup. Options are:

• Heat--Stage3(laststageofheating)--ISU2100,2140,or2170

• Cool:Stage3--ISU2080

• Cool:Stage4--ISU2090

• Geothermalradiantheat:Stage1--(seewiringguideonpages12-13)

• Geothermalradiantheat:Stage2--(seewiringguideonpages12-13)

HEAT STAGE 3 or
COOL STAGE 3 or
COOL STAGE 4
120
VAC
C
Rc
R
U1
U1
U2
U2
24
VAC
Transformer
Thermostat
C
R
1
1
2
3
MCR32952
HEAT STAGE 3
120
VAC
C
Rc
R
U1
U1
U2
U2
24
VAC
Transformer
120
VAC
24
VAC
Transformer
Thermostat
C
R
C
R
1
1
2
3
MCR32953
69-2490_B.indd 14 7/13/2011 1:41:57 PM