Hoover C1660-900 user manual Belt replacement, When to replace, How to replace

Models: C1660-900

1 28
Download 28 pages 19.54 Kb
Page 9
Image 9

3-15

L

Replace lens - Reposition lens (L) and secure with the two screws.

Belt replacement

The belt on your Hoover cleaner causes the agitator to rotate and is important for the effective operation of the cleaner.

The belt is located under the hood of the cleaner and should be checked from time to time to be sure it is in good con- dition.

When to replace

Disconnect cleaner from electrical outlet.

To check belt, remove hood and agitator cover as shown in Figs. 3-16 through 3-

19.Replace belt if it is stretched, cut or broken.

What to buy

To assure effective operation, use only genuine HOOVER belts with your cleaner. When purchasing a new belt, ask for HOOVER part No. 38528040 (belt package part no. 40201190).

3-16

How to replace

Disconnect cleaner from electrical outlet.

With the handle in the upright position, tilt cleaner back until it rests on floor.

Remove the 2 screws near the front of the brush roll cavity.

3-17

A

Press on handle release pedal (A) and lower the nozzle so it is flat.

Remove hose end (Fig. 2-13).

Remove 2 screws at rear of hood.

3-18

Lift hood off cleaner.

3-19

B

Remove the 2 screws behind the agitator cover.

Remove agitator cover (B).

3-20

Remove agitator and used belt.

Discard used belt.

3-21

C

With lettering to the outside of belt, slide new belt along side of cleaner cavity and over motor pulley (C).

3-22

D

Insert agitator through belt and place belt in belt guide (D).

Continued

9

Page 9
Image 9