Installation

4
Installation andVentilation requirements
IMPORTANT: This dryer must be
installed such that the air inlets and
outlet are not restricted (fig. 1).
There should be a gap of at least 12mm
(0.5 inches) between the sides and rear of
the machine and the surrounding walls and
cabinets.
To ensure adequate ventilation the space
between the bottom of the machine and the
floor must not be obstructed.
NEVER install the dryer up against
curtains.
Prevent items from falling or collecting
behind the dryer as these may obstruct the
air inlet and outlet.
A venting hose is supplied with this
tumble dryer.
Use the venting hose to exhaust hot air to
the external atmosphere. This installation
ensures the maximum drying efficiency and
reduction of steam in the drying room.
If the dryer is installed under a worktop or
built-in, it is essential to use the venting
hose to carry the hot moist air away from
the dryer otherwise re-circulation of the
moist air will prevent the dryer from
working efficiently.
The hose may be fitted through a wall or
through an open door or window (fig.2).
The hose is 95mm (3.75 inches) in
diameter and will extend up to 1.8 metres
(6 feet).
Venting hoses longer than 1.8 metres
(6 feet) are not recommended as the dryer
performance will be reduced.
Ensure that the venting hose is not
kinked as this will prevent the dryer
from working efficiently.