5. TROUBLESHOOTING

If a minor problem occurs, it usually can be solved quite easily when the cause is found by using the checklist below.

Any other servicing should be done by an authorized service representative.

! WARNING !

To reduce risk of personal injury - unplug vacuum before servicing.

PROBLEM

POSSIBLE CAUSE

POSSIBLE SOLUTION

 

 

 

 

 

Vacuum won’t

1.

Power cord not firmly plugged

1.

Plug unit in firmly.

run

 

into outlet.

 

 

 

2.

Blown fuse or tripped breaker.

2.

Check fuse or breaker in home. Replace

 

 

 

 

fuse/reset breaker in home.

 

4.

Thermal Protector activated.

4.

Unplug and allow vacuum to cool for 30min.

 

 

 

 

(This willl reset the thermal protector)

System Check

1.Rinsable Filter and/ or Filter

1.

Clean Rinsable Filter and or Filter made

Indicator has

made with HEPA media is dirty.

 

with HEPA media - Pg.9

turned red

2.

Dirt cup full and/ or clogged.

2.

Empty dirt cup - Pg.8.

or

Vacuum won’t

3.

Broken or worn belt.

3.

Replace belt - Pg.12.

pick up

4.

Brushroll and/ or Hose

4. Check Hose - Pg.11. Check Brushroll - Pg.10.

or

 

clogged.

 

 

Low suction

 

 

 

5. Carpet height setting is

5.

Set Carpet Height Adjustment to appropriate

 

 

 

incorrect.

 

setting for carpet being cleaned - Pg.7.

 

6.

Suction Only Mode is ON.

6.

Step on Brushroll ON/OFF Pedal to turn

 

 

 

 

Suction Only Mode OFF

Dust escaping

1.

Dirt cup full.

1.

Empty dirt cup - Pg. 8.

from vacuum

2.

Dirt cup not installed correctly.

2.

Review Dirt Cup removal & replacement -

 

 

 

 

Pg. 8.

 

3.

Hose not installed correctly.

3.

Review Hose installation - Pg. 7.

 

4.

Rinsable and/ or Filter made

4.

Review Filter Removal and Cleaning.

 

 

with HEPA media not installed

 

 

 

 

completely.

 

 

Headlight not

1.

Bulb burnt out.

1.

Replace bulb - Pg. 11.

working

2.

Loose electrical wires.

2.

Call 1-800-944-9200 for nearest authorized

 

 

 

 

 

Hoover® dealer.

Vacuum is

1.

Carpet height setting is

1.

Set Carpet Height Adjustment knob to

difficult to push

 

incorrect.

 

appropriate setting for carpet being cleaned

or won’t move

 

 

 

- Pg. 7.

forward

 

 

 

 

Powered Hand

1.

Too much pressure being

1.

Continue using tool applying light pressure.

Tool brushroll

 

applied to tool.

 

 

won’t turn

2.

Blockage.

2.

Remove blockage - Pg. 11

 

 

3.

Low vacuum suction.

3.

Check items under “Vacuum won’t pick or

 

 

 

 

Low suction.”

Smoky/burning

1.

Belt broken or stretched.

1.

Replace brushroll belt - Pg. 11.

smell detected

2.

Brushroll is clogged.

2. Clear/ remove debris from brushroll - Pg. 10.

 

13

Page 13
Image 13
Hoover UH70200 owner manual Troubleshooting