Hoshizaki AM-50BAE-ADDS, AM-50BAE-DS F. Water Supply and Drain Connections, Fig

Models: AM-50BAE-DS AM-50BAE-ADDS AM-50BAE-AD

1 34
Download 34 pages 44.48 Kb
Page 24
Image 24
F. Water Supply and Drain Connections

F. Water Supply and Drain Connections

Manual backgroundWARNING

1.Water supply and drain connections must be installed in accordance with applicable national, state, and local regulations.

2.Normal operating water temperature should be within 45°F to 95°F (7°C to 35°C). Operation of the icemaker, for extended periods, outside of this normal temperature range may affect icemaker performance.

3.To prevent damage to equipment, do not operate the icemaker when the water supply is off, or if the pressure is below 10 PSIG. Do not run the icemaker until the proper water pressure is reached.

A plumbing permit and services of a licensed plumber may be required in some areas.

External filters, strainers, or softeners may be required depending on water quality.

Contact your local Hoshizaki distributor for recommendations.

Water supply inlet is 1/2" female pipe thread (FPT). A minimum of 1/4" nominal ID copper water tubing or equivalent is required for the water supply line.

A water supply line shut-off valve and drain valve should be installed.

Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG.

If the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.

Drain outlet is 1/2" FPT. A minimum of 1/2" nominal ID hard pipe or equivalent is required for the drain line.

Drain line should not be piped directly to the sewer system. An air gap of a minimum of

2 vertical inches (5 cm) should be between the end of the drain pipe from the icemaker and the floor drain.

For gravity drain installation, drain line must have 1/4" fall per foot (2 cm per 1 m) on horizontal runs to get good flow. A vented tee connection is also required for proper flow.

For optional drain pump installation, refer to the instruction manual included with the

pump.

Minimum 1/4" Nominal ID

 

 

 

 

Copper Water Tubing

 

Water Supply Line

 

Shut-Off Valve

 

 

 

Water Supply Inlet

 

Water Supply Line

1/2" FPT

 

 

 

Drain Valve

 

Piping to approved drain. Leave a 2‑inch (5-cm) vertical air gap between the end of the pipe and the drain.

Vent Tube

2-inch (5-cm) air gap

Drain Outlet

1/2" FPT

 

 

Minimum 1/2"

 

 

DrainFloor

Fig. 30

Nominal ID Hard Pipe

 

24

Page 24
Image 24
Hoshizaki AM-50BAE-ADDS, AM-50BAE-DS instruction manual F. Water Supply and Drain Connections, Fig