19
4. Controls and Adjustments
CAUTION
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact
Hoshizaki Technical Support at 1-800-233-1940.
a) Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions:
S4 Dip Switch
S4 Dip Switch No. 1 2 3 4 5 6 7 8 9 10
KM-2500SWH3 OFF OFF OFF OFF OFF OFF OFF OFF OFF ON
KM-2500SRH3 OFF OFF OFF OFF OFF OFF OFF OFF OFF ON
b) Harvest Timer (S4 dip switch 1 & 2)
The harvest timer starts when the thermistor warms to 48°F (9°C) at the evaporator
outlet and the control board reads the thermistor's 3.9 kΩ signal. The harvest timer is
factory set, and generally no adjustment is required. However, a setting longer than the
factory setting may be advised in cases where the ush provided at harvest needs to be
prolonged for extra cleaning. Before changing this setting, contact Hoshizaki Technical
Support at 1-800-233-1940 for recommendations. Keep in mind that setting the harvest
timer to a longer setting will decrease 24 hour production.
Note that the pump-out timer (S1 dip switch 3 & 4) acts in place of the harvest timer
during cycles with a pump-out. For details, see "II.C.4.c) Pump-Out Timer (S1 dip
switch 3 & 4)."
S4 Dip Switch Setting Time
(seconds)
No. 1 No. 2
OFF OFF 60
ON OFF 90
OFF ON 120
ON ON 180
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5 & 6)
Pump-Out Timer (3 & 4)
Harvest Timer (1 & 2)
Bin Control Selector (7)
Factory Use (8)