Hotpoint E6002 manual Installation - Model E600, X Cei, Installing built-in hobs

Models: E6002 E600

1 16
Download 16 pages 52.85 Kb
Page 9
Image 9
Installation - Model E600

Installation - Model E600

These instructions are intended for the qualified technician installing the appliance in order to insure that the installation, adjustments and maintenance procedures are performed correctly and comply with the regulations currently in effect.

Important: the hob must be disconnected from the power supply before making any adjustments or performing any maintenance, etc.

Installing built-in hobs

The hob has a type X protection rating against overheating in compliance with regulation CEI 335-2-6. Therefore, the hob cannot be installed alongside of cabinets which are higher than the surface of the hob itself. The following precautionary measures should be observed in order to ensure proper installation:

a)Hoods must be installed in compliance with the required specifications contained in the instruction manual for the hood itself.

b)The built-in ceramic glass top can be installed on any counter top as long as it is 600 mm or more in width and resistant to temperatures of up to 100°C. The dimensions and the position of the hole are shown in fig..

Insert the hob into the hole, pressing firmly around the frame to make it adhere to the counter top. Important: The surface where the hob is installed must be perfectly flat. Deformations caused by improper installation may affect the characteristics of the hob, and, therefore, its performance.

c)If a wooden panel is installed beneath the hob for insulation purposes, it must be positioned at least 20 mm from the bottom part of the hob itself.

Note: If the hob is installed above a built-in oven, it is preferable that the oven be installed in such a way that it is set on two strips of wood; if, on the other hand, the oven is installed on a continuous base, there must be an opening in the back of at least 45 x 560 mm.

.

45

mm.

mm

 

560

 

 

39 mm.

505

. mm

575mm.

48 mm.

 

 

 

 

 

-2

 

 

.

+0

560 mm. +0 -2

 

 

490

mm

 

 

 

 

 

If the hob is installed above a built-in oven equipped with a forced air cooling system, air intake and exhaust slots must be provided to ensure that the air circulates properly within the cabinet. Figures provide illustration of possible installation solutions.

X (CEI 335-2-6)

These measurements must absolutely be observed in so far as improper installation can cause the surrounding surface areas to overheat. It is recommended that the hob be installed at a distance of at least 40 mm from the back wall or other vertical surfaces to ensure that the air circulates properly over the cooking area and to avoid overheating the surrounding surfaces. A seal or gasket is provided with the hob; make sure that it adheres properly to the bottom part of the frame of the

hob. The seal must fit properly around the entire hob frame and especially along the corners in order to create a seal between the counter top and the cooktop itself so as to prevent spills or splashes from leaking into the cabinet below. Fasten the 4 hooks supplied into the slots as shown in Fig.;

Fastening diagram for the hooks

A

A

 

30

40

A

A

 

Fastening positions

Hook placement for

 

40 and 30 mm tops

 

 

9