Technical characteristics
Electrical connection
•The electrical safety of this appliance can only be guaranteed if the latter is correctly and efficiently earthed, in compliance with regulations on electrical safety. Always ensure that this vital safety measure has been taken. If you have any doubts, call in a qualified technician to check the electrical system thoroughly.
•The manufacturer denies all responsibility for damage resulting from a system which has not been earthed correctly.
•Before powering the appliance, check whether the technical characteristics featured on the appliance data plate correspond with those of the mains electrical system.
•Check that the current load of the mains supply and of the power sockets is suitable for the maximum power of the appliance, indicated on the appliance data plate. If in doubt, contact a qualified professional.
Disconnect the appliance from the electricity supply before all operations.
Connect your hob to the electrical system by means of a junction box: if the appliance is connected permanently to the mains, an omnipolar circuit breaker, accessible if necessary, with a minimum contact opening of 3 mm should be installed.
Valid only for models with a power supply cable for
Some models are supplied with a
Some models are not fitted with a power supply cable, as the cable should be sized according to the type of electrical connection in use (see connection table below).To connect the cable, proceed as follows:
•Using a screwdriver, prise on the side tabs of the terminal board cover;
•Pull open the cover of the terminal board.
To install the cable, proceed as follows:
•unscrew the wire clamp screw and the contact screws.
•to make the desired electrical connection (see table), use the jumpers housed inside the box. Position the power supply cable wires according to the indications in the table.
•once the connections have been made, tighten all the terminal screws fully.
•Fasten the supply cable in place with the clamp and close the cover of the terminal board.
| Electrical connections |
|
|
| Voltage, | Fuses, | ||||||||
|
|
|
| Frequency | Sections | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |||
1 | 2 | 3 | 4 | 5 |
|
|
|
|
| 25 A* | ||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| 2,5 mm² | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| L |
|
|
| N |
|
|
|
| |||||
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*Application of the simultaneity coefficient in accordance with cei
This appliance conforms with the following European Community Directives:
-73/23/EEC of 19/02/73 (Low Voltage) and subsequent amendments;
-89/336/EEC of 03/05/89 (Electromagnetic compatibility) and subsequent amendments;
-93/68/EEC of 22/07/93 and subsequent amendments;
Warning: If the hob is fitted above a
6